Leg" Function - Automatic Thermal Disinfection - Bosch Compress 3000 DW FOO Installation Instructions Manual

Electric heat pump water heater hp 270-2e 0 foov/s...
Hide thumbs Also See for Compress 3000 DW FOO:
Table of Contents

Advertisement

– Start of 1st period
– End of 1st period
– Start of 2nd period
– End of 2nd period
Programming of noise reduction mode periods
▶ Access the „Sil" function.
▶ Press „ok".
A bar flashes at the start schedule of the 1st noise
reduction mode period and "
▶ Use the „+" and „-" keys to set the noise reduction mode
start schedule.
▶ Press „ok".
The flashing bar shows now the stop schedule of the 1st
period and "
" is shown.
▶ Use the „+" and „-" keys to set the noise reduction mode
duration.
▶ Press „ok".
The flashing bar shows the start schedule for the 2nd noise
reduction mode period and "
▶ Use the „+" and „-" keys to set the noise reduction mode
start schedule of the 2nd period.
▶ Press „ok".
The flashing bar shows now the noise reduction mode stop
schedule for the 2nd period and "
▶ Use the „+" and „-" keys to set the noise reduction mode
duration.
▶ Press „ok".
The noise reduction mode periods for days „1 to 5" are now
set.
▶ Repeat the above described operations to set the noise
reduction mode periods for days „6 and 7".
Completed definition of the 2nd noise reduction mode
period for days „6 and 7" concludes the noise reduction
mode programming.
After programming, the display, in the "Prog" sub-menu,
shows SIL with the time bars indicating the periods when
the noise reduction mode will be activated.
Select only one day period
▶ Select the first period according to the previously
mentioned.
▶ Use "+" and "-" keys to set the the start and finish time to the
same period.
The display shows "----".
▶ Press „ok" to confirm.
Switching off the noise reduction mode period
▶ Access the „Sil" function.
Compress 3000 DW FOO
" is shown.
" is shown.
" is shown.
Appliance status information | 31
▶ Press „ok".
Display shows the start schedule of the 1st noise reduction
mode period flashing.
▶ Use the „+" and „-" keys to set the noise reduction mode
start and finish time to the same period.
The display shows "----".
Repeat for 2nd noise reduction mode period, in case is set.
▶ Press „ok" to confirm.
▶ Press „ok" again and hold it for more than 3s until "Prog"
and "
" goes off.
The first element of the time bar blinks.
▶ Press "menu" to go out of the SIL mode submenu (no
blinking).
The SIL menu will show no time bar.
5.7.3 „Leg" function - automatic thermal disinfection
The „Leg" function allows for the thermal disinfection process.
The bacteria elimination process will be performed
automatically once a week.
Fig. 39
„Leg" function
Activation of the disinfection mode
temporarily replaces any defined
programming.
DANGER: Beware of burns!
Hot water can cause serious burns.
▶ During thermal disinfection the
temperature may rise up to 72 °C at the
top of the tank.
▶ Warn all users of the danger of burns and
the need to perform thermal
disinfection.
The disinfection process will run until stored
water tank temperature at the bottom
reaches more than 60 °C for at least 35
minutes.
6720646160-17.1V
6 720 808 869 (2014/06)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents