26 | Appliance status information
Time/Temperature Relationship in Scalds
Time to produce a serious burn
Tempera
Aged persons/
-ture
children under 5 years
50 °C
2-1/2 minutes
52 °C
Less than 1 minute
55 °C
About 15 seconds
57 °C
About 5 seconds
60 °C
About 2-1/2 seconds
62 °C
About 1-1/2 second
65 °C
About 1 second
68 °C
Less than 1 second
Table 7
5.5

Main menu

Calling up the main menu
▶ Press and hold the "Menu" button for max. 3 seconds.
menu
< 3 s
Fig. 22
Calling up the main menu
Once you have called up the main menu, you can select the
following menus/submenus:
Prog - Operating programs
– Manual
– P1
– P2
– P3
– Hol
– Off
Set - Settings
– Date
– Prog - programming of the operating times
– Leg - thermal legionella disinfection
– Plus - enhanced comfort function
– Hea - heating by electric assistance
– Purg - purge
– Fset - factory settings
Info - Information
Sft - Software version
▶ Use the "+" or "-" button to select the required menu.
▶ Confirm by pressing "ok".
6 720 808 869 (2014/06)
Adults
More than 5 minutes
1-1/2 to 2 minutes
About 30 seconds
About 10 seconds
Less than 5 seconds
Less than 3 seconds
About 1-1/2 seconds
About 1 second
-
+
ok
6720646160-14.1V
To switch to the previous menu:
▶ Press the "Menu" button.
-or-
▶ Do not press any buttons for 15 seconds.
5.6

"Prog" submenu - Operating programs

You can set 6 different operating times in the "Prog" submenu.
Manual
P1
P2
P3
Hol
Off

5.6.1 "Manual" operating mode

Selecting this operating mode puts the appliance into
continuous operation in order to keep the temperature at the
set value for a longer period of time.
Fig. 23
"Manual" operating mode

5.6.2 "P1", "P2" and "P3" operating modes

"P1" operating mode
Selecting this menu causes the appliance to run according to
the factory-set operating times ( "P1" operating mode,
page 26).
"P2" and "P3" operating modes
Selecting this menu causes the appliance to run according to
the user-set operating times ( "P2" and "P3" operating
modes, page 29).

5.6.3 "Hol" mode

In this operating mode, the appliance is switched off 12 hours
after the mode has been set and is switched back on two days
before the end of the set holiday. If necessary, the electric
booster heater is switched on during the set holiday period to
provide "freeze protection".
6720646160-37.1V