Once the appliance is switched back on, the
"Leg" function ( section 5.7.3) is executed
automatically.
Fig. 24
"Hol" operating mode
Switching on the "Hol" function
▶ Call up the "Hol" function.
▶ Press "ok".
The current month flashes on the display.
▶ Use the "+" and "-" buttons to set the month in which the
holiday ends.
▶ Press "ok".
The current day flashes on the display.
▶ Use the "+" and "-" buttons to set the day on which the
holiday ends.
▶ Press "ok".
The "Hol" function is active.
In "Hol" mode, the appliance still operates for
12 hours.
The "Hol" operating mode can be set for a
maximum of 4 months.
▶ Check that the date is correct
(section 5.7.1).
▶ The appliance must be connected to the
mains power supply for correctly run the
Holiday mode.
Deactivating the "Hol" function manually
To deactivate the "Hol" operating mode before the set date:
▶ Call up the "Prog" menu.
▶ Press "ok"
▶ Select "man" (manual mode).
The heat pump will start operating and will initiate a
legionella disinfection.
Compress 3000 DW FOO
Tank freeze protection
The electric booster heater starts up when the water
temperature in the tank falls below 5 °C and switches off again
when the temperature reaches 8 °C.

5.6.4 "OFF" operating mode

In this operating mode, the appliance is switched off. If
6720804054-01.1V
necessary, the electric booster heater is switched on by itself
for the tank anti-freeze protection function.
The legionella disinfection cycle is ensured once per week
according to the schedule, to ensure that the appliance is ready
to be safely used immediately after being set back to any of the
normal operation modes.
Fig. 25
5.7
You can set various parameters in the "Set" submenu:
Date
Prog - timetable operating programing
Leg - legionella
Plus - enhanced comfort function
Hea - heating by electric assistance
Purg - purge
Fset - factory settings
Appliance status information | 27
In case of manual "Hol" deactivation do not
use hot water before the legionella
disinfection is completed, unless the last
disinfection has occurred less than 7 days
ago.
In "OFF" mode the anti-freeze and weekly
LEG functions are assured.
"OFF" operating mode

"Set" submenu - Settings

6720646160-10.1V
6 720 808 869 (2014/06)