TROUBLESHOOTING
Troubleshooting Symptoms
No Power at AC Receptacles
POSSIBLE CAUSE
Output indicator is OFF, and
overload indicator is ON
AC circuit protector tripped Check the AC load and reset circuit protector
Faulty power tool or appli-
ance
Faulty generator
Engine Stops or Loses Power
POSSIBLE CAUSE
Out of fuel
Fouled, worn, incorrect, or
defective spark plug; incor-
rect spark plug gap or heat
range
Loose ignition connections
Water present in fuel /
incorrect fuel
Kinked or plugged fuel tank
vent line
SMART throttle control
malfunction
No / low oil in the engine
Clogged air filter
Overheated engine
Mechanical failure
70
Check the AC load; stop and restart the engine
Check the cooling air inlet; stop and restart the engine
Replace or repair the power tool or appliance; stop and
restart the engine
Take the generator to an authorized POLARIS servicing
supplier or refer to the service manual
Refuel
Inspect, clean, and / or replace the spark plug, set the
spark plug gap to specification
Check all connections and tighten
Drain the fuel system and refuel
Inspect and replace
Take the generator to an authorized POLARIS servicing
supplier or refer to the service manual
Check / replace oil
Clean or replace the air filter(s)
Clean cover screens
Take the generator to an authorized POLARIS servicing
supplier or refer to the service manual
SOLUTION
SOLUTION
Need help?