Power Management - Polaris Power P1000i Operator's Manual

Polaris power p1000i/ p2000i generator
Hide thumbs Also See for Power P1000i:
Table of Contents

Advertisement

OPERATION
Safe Operating Precautions

Power Management

DEVICE
Paint Sprayer
Radio
Total Running (Rated) Watts = 660
Additional Starting Surge Watts = 1380
Total Generator Output Required = 2040
Ensure the combined electrical rating of the powered device(s) do not
exceed the maximum allowed by the generator. Never exceed the
maximum power rating of the generator. Power levels between rated and
maximum may be used for no more than 30 minutes.
DC Operation
Connecting the Battery Charging Cable (included)
The battery emits explosive hydrogen gas during normal operation. A
spark or flame can cause the battery to explode with enough force to kill
or cause serious injury. Wear protective clothing and eye protection when
charging a battery.
Battery posts, terminals, and related accessories contain lead and lead
components. Wash hands after handling.
The DC charging output is not regulated. The DC receptacle should only
be used for charging 12V DC batteries.The 12V DC receptacle has no
battery overcharge protection function. Do not overcharge the battery.
When using the DC output, position the SMART throttle switch to OFF.
The DC receptacle may be used while the AC power is in use.
34
RUNNING
(RATED) WATTS
360
300
ADDITIONAL
STARTING (SURGE)
WATTS
1080
300

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Power p2000i