Confirm The Refrigerant - LG 3828A30087S Installation Manual

Lg room air conditioner installation manual
Table of Contents

Advertisement

Installation

Confirm The Refrigerant

1. Check the quality label on the indoor and outdoor unit.
2. Make certain that the refrigerant is R-410A.
NOTICE
THIS PRODUCT CONTAINS R-410A REFRIGERANT
1) Different compressor oil
- R-410A(Polyol ester) / R-22(Mineral).
- Do not mix the existing mineral oil.
- Do not apply used pipe, tools and gauges covered with the existing mineral oil.
2) Absorption of moisture
-Compressor's oil has the high absorption rate of moisture.
3) Composition
- R-410A(R32:R125=50:50wt%).
NOTE: Never mix with other refrigerants
Example : Split type 12,000 Btu/h
120
100
100
80
60
40
20
0
R-410A
100%
R-22
0%
4) High pressure.
- 1.6 times higher than R-22.
- High Pressure refrigerant may cause personal injury.
Boiling Pt.(°C)
R-410A
R-22
Do not handle the pipe by yourself (customer) High-pressure refrigerant may cause personal injury.
- manifold gauge ,charging and any piping tools must be dedicated to R-410A systems.
12 Room Air Conditioner
93
89
70%
50%
30%
50%
Vapor pressure(25°C)(kg f/cnf)
-51.4
-40.8
84
76
30%
0%
70%
100%
15.9
9.6
Vapor density(25°C)(kg/m
64
44.4
2
)