Confirm The Refrigerant - LG LA121CNM Installation Manual

Lg la121cnm: install guide
Hide thumbs Also See for LA121CNM:
Table of Contents

Advertisement

Available languages

Available languages

Installation

Confirm The Refrigerant

1. Check the quality label on the indoor and outdoor unit.
2. Make certain that the refrigerant is R-410A.
NOTICE
THIS PRODUCT CONTAINS R-410A REFRIGERANT
1) Different compressor oil
- R-410A(Polyol ester) / R-22(Mineral).
- Do not mix the existing mineral oil.
- Do not apply used pipe, tools and gauges covered with the existing mineral oil.
2) Absorption of moisture
-Compressor's oil has the high absorption rate of moisture.
3) Composition
- R-410A(R32:R125=50:50wt%).
NOTE: Never mix with other refrigerants
Example : Split type 12,000 Btu/h
120
100
100
80
60
40
20
0
R-410A
100%
R-22
0%
4) High pressure.
- 1.6 times higher than R-22.
- High Pressure refrigerant may cause personal injury.
Boiling Pt.(°C)
R-410A
R-22
Do not handle the pipe by yourself (customer) High-pressure refrigerant may cause personal injury.
- manifold gauge ,charging and any piping tools must be dedicated to R-410A systems.
12 Room Air Conditioner
93
89
70%
50%
30%
50%
Vapor pressure(25°C)(kg f/cnf)
-51.4
-40.8
84
76
30%
0%
70%
100%
15.9
9.6
Vapor density(25°C)(kg/m
64
44.4
2
)

Advertisement

Table of Contents
loading

This manual is also suitable for:

La121hnm

Table of Contents