Basler BIP2-XXXXc User Manual page 91

Ip fixed box cameras
Table of Contents

Advertisement

AW00097209000
Camera
+5
VDC
1 kΩ
Fig. 11: I/O Schematic, Variant 1 (Input Port Connected to Ground via Switch)
Fig. 12: I/O Schematic, Variant 2 (Input Port Connected to Input Voltage)
Basler IP Fixed Box Cameras
Alt. Camera Power
+5
VDC
(Set as an output)
+5
VDC
1 kΩ
(Set as an output)
+5
VDC
1 kΩ
(Set as an input)
RS-485 A+
RS-485 B-
+5
VDC
1 kΩ
(Set as an input)
RS-485 A+
RS-485 B-
+12 to +24
VDC
3
2
DC Out
4
I/O-0
6
I/O-1
Switch
8
I/O-2
1
Gnd
5
7
8
I/O-2
0 to +24 VDC
1
Gnd
5
7
The Terminal Connector
+24
VDC
Max
Device
RS-485 Gnd
RS-485 A+
RS-485 B-
Device
RS-485 Gnd
RS-485 A+
RS-485 B-