Winnebago Voyage 2005 User Manual page 98

Table of Contents

Advertisement

SECTION 13
SLIDEOUT ROOM
In the event of a total system failure where
Manual Mode cannot be used, two crank handles
may be used to retract or extend the room.
Crank-In Mode:
If the room will not retract using the buttons
and the mechanism is apparently malfunctioning,
you may need to manually crank the room in to
the travel position. The cranks are stored on clips
on the wall of the right rear cargo compartment.
Slideout Cranks
To use the crank handles, open the luggage
compartment doors exposing the front of each
room slide mechanism. Insert the crank handle
into the tube and align the drive pin at the rear of
the tube with the notches in the crank handle. It
may be necessary to move the handle slightly
from side to side.
The crank handle will only move the arm that
it is inserted into. Consequently you will need to
alternate between each crank handle on each side
to move the room in or out. If help is available, a
second person cranking on the other handle si-
13-4
multaneously will greatly speed up the process.
At no point in the cranking process should you let
one side get more than 2 inches (50 mm) ahead of
the other. The most effective way to retract the
room using a single person is to crank one side
ahead of the other than crank the other side in
(walk the room in).
Troubleshooting
Problems Extending the Room
Set the Park Brake if the red Park Brake light
flashes while pressing the Extend button.
Green light will flash
error code, if system malfunctions
Diagnostics
Red light will flash if park
Reset Button
If an error is detected, the green LED on the
left side of the control panel will blink an error
code. If an error code appears, see the On Board
diagnostics section to determine the problem.
The error code must be cleared prior to operating
the room. To clear the error, press the "RESET"
button with a small tool such as a toothpick. Be-
fore operating the room after an error has been
detected, check for obvious faults such as ob-
structions before trying to operate the room
again. If the error code appears again, the room
will need to be extended using the crank method
described in the previous section. The crank
method is provided as a means to extend the
room if there is a failure in the automatic system.
If the room must be extended using the crank
method, keep in mind it is likely that it must also
be cranked in to retract. After the outing is com-
pleted and the room is retracted fully, take the
brake not set.