3.2 Batteries

3.2.1 Operating Principles

Charging / first-time
use
Operation /
Discharging
The battery must be charged prior to using it for the first time because it is deliv-
ered with an energy content as low as possible.
The permissible temperature range for charging is between 0°C to +40°C/ +32°F
to +104°F. For optimal charging, we recommend charging the batteries at a low
ambient temperature of +10°C to +20°C/+50°F to +68°F if possible.
It is normal for the battery to become warm during charging. Using the chargers
recommended by Prexiso, it is not possible to charge the battery if the temper-
ature is too high.
For new batteries or batteries that have been stored for a long time (> three
months), it is effectual to make only one charge/discharge cycle.
For Li-Ion batteries, a single discharging and charging cycle is sufficient. We
recommend carrying out the process when the battery capacity indicated on the
charger or on a Prexiso product deviates significantly from the actual battery
capacity available.
The batteries can be operated from -20°C to +55°C/-4°F to +131°F.
Low operating temperatures reduce the capacity that can be drawn; high oper-
ating temperatures reduce the service life of the battery.