10.0

OPERATING THE APPLIANCE

Read All Instructions Before Use
Check that the heater outlet grille, mounted at the top of the appliance, is not covered or
obstructed in any way, and ensure the power to the fire is switched on. The appliance is con-
trolled using four switches mounted at the right hand side towards the top.
The first switch towards the front, marked (0I), controls the main power to the appliance and
switches on the visual light display. This feature can be used independently of the heating fea-
tures.
*
The next switch marked (
) operates the fan blower without heat, and can be used for cool air
circulation. However for this feature, the main power switch (0I), must also be in the "on" posi-
tion.
The next switch with a "single bar" marked (I) operates the low heat, (1kW), setting.
The switch with "two single bars" marked (II), operates the high heat, (2kW) setting.
To operate the fire in any of the above modes, the left hand switch marked (OI) must be
switched to the "on" position.
To operate the fire, the first switch must be turned on firstly, followed by the second switch to
start the blower, if required. To obtain heat from the appliance, the I switch must then be oper-
ated for LOW heat, followed by the II switch for the HIGH heat setting.
The appliance can be switched off at any time, irrespective of the particular mode select-
ed, by simply switching the first switch marked (OI) to the "off" position.
It is also recommended to unplug the power supply cable at the supply outlet when not in
use.
11.0
SAFETY CUT-OUT SYSTEM
This appliance has a safety cut-out system fitted which will activate if the air inlets or heater out-
lets are obstructed. For safety reasons the fire WILL NOT switch on again automatically.
NOTE: The visual light effect will remain operational if the cut-out is activated, only the fan
heater elements are prevented from operating.
The following procedure must be carried out before the fire can be operated again:
1. Unplug the power supply cable at the outlet socket and place all switches to off at the
appliance.
2. Leave the fire OFF for a period of not less than 10 minutes, ensuring any obstructions are
removed.
3. Plug in the power supply cable at the outlet socket, and then switch on at the appliance.
If the appliance fails to operate correctly, repeat the above procedure.
If an attempt to switch on is made before the safety cut-out has reset, the heaters may cut-out
for a further period of time. If the sequence has been followed correctly and the heaters still fail
to function, check the power supply cable plug is plugged in at the outlet socket. If this is not
the cause, call an electrician.