Other Items (Nos. T01 To - Sony SRW-5000 Operation Manual

Hd digital videocassette recorder
Hide thumbs Also See for SRW-5000:
Table of Contents

Advertisement

Item number
Item
A10
9-Pin TC sense
select
A20
Black Clip for 444 to
422 Conversion

Other Items (Nos. T01 to ...)

Item number
Item
T01
AUTO REPEAT
MODE
T02
INTERNAL VIDEO
SIGNAL
GENERATOR (HD)
T04
INTERNAL AUDIO
SIGNAL
GENERATOR
Setting
Function
[LINE]
Specifies whether or not the time code information of FC
FC
output signal is returned when time code sense command
is input through the 9-pin connector.
LINE: Time code information of main output signal is
FC: Time code information of FC output signal is returned.
Notes
• Pulldown output signal and 30-frame/sec time code are
• When editing pulldown output signals with a VTR
[on]
When a 4:4:4 signal is converted to a 4:2:2 signal, this item
off
specifies whether the signal that goes below the black level
(040H) is suppressed or not.
on: Signals that drop below the black level are suppressed.
off: Signals that drop below the black level are not
Setting
Function
[off]
Selects the repeating operation of PREVIEW in automatic
on
editing.
off: PREVIEW in automatic editing is not repeated.
on: PREVIEW in automatic editing is repeated. To stop,
[off]
Selects the test signal output by the signal generator built
COLOR BARS(100%)
into the VTR.
COLOR BARS(75%)
off: The test signal is not generated, and the VTR operates
MULTI BURST 1
MULTI BURST 2
all other settings: The test signal is output from the VTR. At
10 STEPS
PULSE & BAR
RAMP
BLACK
[off]
Selects the operation of audio test signal output.
silence
off: The audio test signal is not output.
1 kHz sine
silence: Muted signal.
1 kHz sine: 1 kHz (In this case, a 1 kHz -20 dB FS sine
Notes
• When "silence" or "1 kHz sine" is selected, the AUDIO IN
• When the unit is operated in the 23.98 PsF or 24 PsF
returned. In pulldown conversion mode, 24-frame/sec
time code information is returned.
In pulldown conversion mode, 30-frame/sec time code
is returned.
synchronized only when this unit is set to PLAY LOCK
mode. To synchronize the signals, set item A05 "PD EXT
SD REF LOCK MODE" to "lock2".
operating in 30F mode, it may not be possible to achieve
sync within 5 seconds. If this occurs, set the preroll time
to 7 seconds.
Also, normal operation is not possible with devices
engaged in player sync.
suppressed.
press the STOP button.
normally.
this time it is also possible to record the signal.
wave is supplied to all audio inputs.)
and AUDIO MONITOR L/R buttons light up.
mode with "1 kHz sine" selected, the output signal is
960 Hz.
179
Menu List

Advertisement

Table of Contents
loading

This manual is also suitable for:

Srw-5500

Table of Contents