Lexicon PCM 80 User Manual page 51

Lexicon user guide digital effects processor pcm 80
Hide thumbs Also See for PCM 80:
Table of Contents

Advertisement

Once you have assigned a Destination, press Load /
display.
Patch 0
000:
Src values are shown here. The asterisk ( ) indicates
that this field is available for control with the ADJUST
knob (and that additional parameters are available by
pressing Load / ).
This display allows you to assign Destination values to specific Source values.
These assignments are made in pairs, each with a value for the Source and a
value for the Destination. For example, the default is two pairs mapped as
follows:
minimum Src value (0) = minimum Dst value
maximum Src value (127) = maximum Dst value
This establishes a linear relationship between the parameter and the controller.
Inverse control is accomplished easily by reversing these settings. As many as
eight pairs of Destination/Source values, or pivot points, can be assigned here,
providing an exciting new level of dynamic control.
When creating patches, there are situations in which you will want to leave the
Patch row to adjust parameters. To make this convenient, a Jump command is
available. Jumping is dependent on the current Patch display, and is activated
simply by pressing Edit while a certain display is active. This will jump you out
of the Patch row and to the location where you can make the necessary
adjustments. Pressing Edit again will jump you back to the Patch Row. (Note
that using any front panel controls other than those required to adjust the
parameter to which you have jumped, will disable the jump. This is not
catastrophic, but it will require you to return by using Up and Down and
SELECT.) The following Jumps are available:
From the Patch row Src display:
• With ADJUST selected as the Source, press Edit to jump to the Controls
row, where you can specify range limits for the ADJUST knob. Press Edit
again to return to the Patch row.
• With any modulation parameter selected as a Source, press Edit to jump
to the Modulation row position of the Source. For example, if the Patch
source LFO is displayed, press Edit to jump to Modulation row position 0
(LFO) where you can edit any LFO parameter value. Press Edit again to
return to the Patch row.
The current Dst value is displayed here. When you press
Values
Load / again, the asterisk will move to indicate that this value
Off
is available to be changed by turning ADJUST.
Assigning Values
to get to the Values
Patch 0
000:
Jump
Basic Operation
Values
Off
2-33

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pcm 80 - rev 1

Table of Contents