The options of display images are described in Table 6.
Data displayed
Current and set
In idle mode, the display does not show current temperature in the boiler, or this
temperature in
imaging can be achieved with arrows UP / DOWN (symbol °C). If network voltage is
boiler
not available, dashes are displayed.
Amount of
Using the UP / DOWN arrows, approximate amount of available water after mixing to
available water
40°C can be displayed after hitting the litre symbol. If no power supply is available, or
mixed to 40°C
it the water temperature in the heater is below 40°C, zero amount shows.
As result of higher single hot water withdrawal a zero amount can be displayed (even
BARGRAPH will not show on the display), despite water warmer than 40°C will flow
out of the heater. This is caused by complex dynamic phenomena that develop when
the boiler is filled with new cold water. Once water stabilises and distributes,
numerical data will be displayed again.
Heating element
The symbol on the display indicates activity of the heating element.
activity indication
Energy
Using the UP / DOWN arrows approximate amount of consumed electricity after
consumption with
hitting the kWh symbol can be displayed - the electronics from the element output
resetting option
and the time of its run counts with the energy consumed from the last reset.
Clock and date
The thermostat contains backed up actual time clock.
"ANTIFROST"
If the boiler is switched off, this function prevents temperature drop below +5°C. If
heating takes place despite that, the snowflake symbol shows on the display if the
temperature drops below +5°C and the ANTIFROST function activates.
Thermal fuse
If the mechanical thermal fuse opens, the fuse symbol shows on the display.
opening indication
Table 6

3.3 CONTROL

The thermostat can be controlled by means of the UP, DOWN, RIGHT, LEFT and OK keys.
Short press is a press shorter than 3 seconds.
Long press is a press longer than 3 seconds.
Simultaneous press is a press of two keys at once that lasts longer than 3 seconds.

3.3.1 THERMOSTAT MODE SETTING

Setting the mode is possible after simultaneous pressing the RIGHT and LEFT keys longer than 3 seconds
(protection against unintended mode switching). Once the set mode symbol starts flashing, you can use the
RIGHT or LEFT keys to switch between the modes.
NORMAL
SMART (If SMART is selected the first week of "learning", both the NORMAL and SMART symbols
are active on the display and later also the SMART symbol);