Putting Out Of Service, Discharge; Inspection, Maintenance & Care For The Appliance - Dražice OKHE 80-SMART Operating And Installation Manual

Tank-type water heater for vertical mounting
Hide thumbs Also See for OKHE 80-SMART:
Table of Contents

Advertisement

2.6 PUTTING OUT OF SERVICE, DISCHARGE

If the hot water heater is put out of service for a longer time, or if it is not going to be used it
has to be drained and disconnected from the electric supply network on all poles. The switch
for the supply lead or the fuse cut-outs have to be shut off.
At places with permanent risk of frost the hot water heater must be drained before the cold
season starts if the appliance remains out of service for several days and if the power supply
is disconnected. Alternatively, an antifreeze protection can be activated (refer to the
PROG/ANTIFROST function).
Drainage of service water shall be performed after closing the shut-off valve in the cold
water supply piping (through the discharge valve for safety valve combination), and with
simultaneous opening of all hot water valves of connected fittings. Hot water may outflow
during the drainage! If there is a risk of frost it has to be considered that not only the water
in the hot water heater and in the hot water piping may get frozen but also the water in the
entire cold water supply piping. It is therefore advisable to drain all fittings and piping that
carry water, up to the part where the house water meter is installed (connection of the
house to water main) which is not jeopardised by frost. When the tank is to be used again, it
has to be filled with water and one needs to make sure that the water flowing out at the hot
water valves did not contain any bubbles.
2.7 INSPECTION, MAINTENANCE & CARE FOR THE APPLIANCE
During the heating process the water that increases its volume during the heating must drip
off the safety valve outlet (in non-pressurised connection this water drips off the
combination faucet valve). In full heating (about 65
3% of the tank capacity. The function of the safety valve has to be checked regularly (based
on the information contained in the attached safety valve manual). In common operation,
such a check needs to be implemented at least once a month, and after each heater
shutdown that exceeds 5 days.
Caution! In doing so, the cold water supply pipe and the connection fitting of the tank may
get heated! If the hot water heater does not work, or if hot water is not withdrawn, no
water shall drip off the safety valve. If water drips, then the pressure in the supply piping is
either too high, or the safety valve is defective. Please call a specialised plumber
immediately!
If water contains too many minerals, an expert has to come to remove the scale that forms
inside the tank, as well as free sediments. This has to be performed after one or two years of
operation. The cleaning is carried out through the hole in the flange by: draining the boiler,
dismantling the flange lid and cleaning the tank. A new sealing has to be used for re-fitting.
Since the inside of the heater has special enamel, the surface of which must not get in
contact with a scale removing agent – do not work with a lime pump. Remove the lime layer
with a timber and suck it off, or wipe it off with a clout. After that, the appliance must be
rinsed thoroughly and the heating process is checked the same as during the initial putting in
operation. Do not use any abrasive cleaning agents or dye thinners to clean the outer shell of
the heater (such as cellulose thinner, trichlor, and the like). For cleaning use a wet clout and
add a few drops of liquid cleaning agent for household applications.