Engaging / Disengaging Cruise
Synchronization:
0 - 5%
F
F
F
N
N
N
R
R
R
N N
SELECT
SYNC
1
F
N
R
N N
SELECT
SYNC
4
Figure 15
Engage:
1. Disengage any other engine mode being
used.
2. Match all engine shift and throttle
settings by moving the active port and
starboard control head levers to within
5% of each other (Figure 15, (1)) and
press the SYNC button (Figure 15, (4))
on the control head. The sync lamp
flashes if the handles are not within 5%
of each other (Figure 15, (3)). The sync
lamp will stop flashing and remain
continuously lit (Figure 15, (4)) when
the levers are moved to within this 5%
range.
A steady sync lamp confirms that the
Cruise Sync is engaged. While the
engines are synchronized, all engine
speeds are matched any time the control
levers are set to within 5% of each other
and are above 20% throttle.
Disengage:
Press the SYNC button on the control head.
6LY3 LDC Operation Manual
F
F
F
N
N
N
R
R
R
N N
N N
SELECT
SYNC
SELECT
SYNC
2
3
F
F
F
N
N
N
R
R
R
N N
SELECT
SYNC
5
0002041
© 2008 Yanmar Marine International
PRODUCT OVERVIEW
DC-DC CONVERTER
DC-DC converter is a type of voltage
converter, which converts direct-current
electricity to arbitrary direct current voltage.
(1)
(4)
(3)
52
1 – 6LY3-LDC Electric Control
System Harness Side
2 – Input Line
3 – Output Line
4 – Relay Harness
Items
Product Name
Model
Input voltage
Output voltage
Output current
Operating temperature
Storage temperature
(2)
83
96.5
133
024522-00X
Switched-mode
DC-DC converter
HADC-20
DC18 - 32 V
DC13.8V (±5%)
15A
-10 - 60°C
-40 - 85°C
21