Yamaha RX-V730 Service Manual page 26

Av receiver/av amplifier
Hide thumbs Also See for RX-V730:
Table of Contents

Advertisement

RX-V730/RX-V730RDS/RX-V630/RX-V630RDS
HTR-5560/HTR-5560RDS/DSP-AX630/DSP-AX630SE
12. DSP RAM CHECK
This menu is used to self-diagnose whether or not the bus
connection for the YSS938 and the external RAM is made
properly.
During signal processing, the status before execution of
this menu is maintained.
The address bus and the data bus are checked and the
connection condition is displayed.
When no error is detected, "NoEr" appears on display.
YSS938 Bus Check
PLD/SRAM BUS CHECK
13. SOFT SW
This menu is used to switch the function settings on P.C.B.
through the software so as to activate the product.
The protection function follows the P.C.B. settings. When
connected to AC or in the maker preset state, the unit is
initialized to the P.C. B. setting. Display of each function
after initialization varies depending on settings on P.C.B.
The operation mode can be changed by selecting the sub-
menu and then using the EFFECT key. With SOF selected
for the SW mode, the settings become effective.
SW MODE: PCB or SOFT can be selected.
MODEL SETTING: V430, V530, AX630, V630, V730 or
DVX can be selected.
TUNER DESTINATION: J, UC, ALG or R can be selected.
38
Display
Description
WAIT
Bus is being checked.
NoEr
No error detected.
DATA
Data bus shorted or open.
RSCS
/RAS or /CAS shorted, or open.
ADDR
Address bus shorted or open.
Display
Description
WAIT
Bus is being checked.
NoEr
No error detected.
DATA
Data bus shorted or open. (XX: 00-07)
ADDR
Address bus shorted or open. (XX: 00-0E)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents