Adjustment Methods - Philips 107E7 Service Manual

17” cdt
Table of Contents

Advertisement

17" CDT Color Monitor
4-3 Adjustment method
1. TP901, B + & HV voltage adjustment:
A. Chroma-2135 Signal generator or PC equivalent set mode 6, UVGA 640X480 pattern 101 .
B. Connect a DC Volt meter between TP902 and ground, then adjust VR902 to be 58±0.2 VDC for CPT CRT
and 59±0.2 VDC for LPD CRT.
C. Set the contrast and brightness max,and then adjust G2=600V for CPT CRT and G2=560V for LG CRT.
2. Factory preset Timings Adjustment:
A. Press MENU Key to show OSD window press Up or Down Key to switch the functional controls.
B. Press the Up Key to select the "ZOOM" function, then press the MENU Key. While do not release the
MENU Key until the OSD window changed to the Factory preset window.
C. The Factory preset window contains the following functional controls. Select one of the control. Then press
the Up/Down Key to adjust its value for the optimum picture.
SR
55
OS
LH
SB
BI
SW
DC
AB
OV
OH
EA
Save SRGB color
Save 5500C color
User OSD size
Brightness
SBQ
Set Burn/in Off & On
Set H/Freq Max 85~72K
DCOffset ADJ
ABL
User OSD VC
User OSD HC
EHT Auto Adjustment
VO
VG
HM
HR
HS
HG
13
V Offset
V Gain
H size Max
H Size Range
HSUB Size Range
H Gain
HBRIOSD VC
HBRIOSD HC
User adjustment
Save and Exit
Degauss
B-Bias
107E7