Product Safety Notice; High Voltage Warning - Philips 107E7 Service Manual

17” cdt
Table of Contents

Advertisement

17" CDT Color Monitor

2-2 .Product safety notice

Many electrical and mechanical parts in this chassis have special safety visual inspections and the protection
afforded by them cannot necessarily be obtained by using replacement components rated for higher voltage,
wattage, etc. Before replacing any of these components read the parts list in this manual carefully. The use of
substitute replacement parts which do not have the same safety characteristics as specified in the parts list may
create shock, fire, X-RAY radiation or other hazards.
2-3.Service notes
1.
When replacing parts or circuit boards, clamp the lead wires around terminals before soldering.
2.
When replacing a high wattage resistor (more than 1/2W of metal oxide film resistor) in circuit board, keep
the resistor about 10mm (1/2 in) away from circuit board.
3.
Keep wires away from high voltage or high temperature components.
4.
Keep wires in their original position so as to reduce interference.

2-4.High voltage warning

Operation of monitor outside of cabinet or with back removed may cause a serious shock hazard. Work on this
model should only be performed by those who are thoroughly familiar with precautions necessary when working
on high voltage equipment.
Exercise care when servicing this chassis with power applied. Many B plus and high voltage terminals are
exposed which, if carelessly contacted, can cause serious shock or result in damage to the chassis. Maintain
interconnecting ground lead connections between chassis and picture tube dag when operating chassis.
Certain HV failures can increase X-ray radiation. Monitor should not be operated with HV levels exceeding the
specified rating for the chassis type. The maximum operating HV specified for the chassis used in this monitor is
25KV ± 0.8KV
with a line voltage of 120/240 VAC. Higher voltage may also increase possibility of failure in HV supply.
It is important to maintain specified values of all components in the horizontal and high voltage circuits and
anywhere else in the monitor that could cause a rise in high voltage or operating supply voltages. No changes
should be made to the original design of the monitor. Components shown in the shaded areas on the schematic
should be replaced with exact factory replacement parts. The use of unauthorized substitute parts may create a
shock, fire or other hazard.
To determine the presence of high voltage, use accurate, high impedance, HV meter connected between second
anode lead and CRT dag grounding device. When servicing the High Voltage System, remove static charge from
it by connecting a 10K ohm resistor in series with an insulated wire (such as a test probe) between picture tube
dag and 2nd anode lead.(AC line cord disconnected from AC power outlet.)
The picture tube used in this monitor employs integral implosion protection. Replace with tube of the same type
number for continue safety. Do not lift picture tube by the neck. Handle the picture tube only after discharging the