Specification; Operating Range - Mitsubishi Electric MS-A09WA Service Manual

Indoor unit wireless type air conditioner
Hide thumbs Also See for MS-A09WA:
Table of Contents

Advertisement

3

SPECIFICATION

Item
Indoor unit model
External finish
Power supply
-
Max. fuse size (time delay)/ Disconnect switch
Min. circuit ampacity
Fan motor
Airflow Low—Med.—High
COOL Dry (Wet)
Moisture removal
Sound level Low-Med.-High
Cond. drain connection O.D.
W
Dimensions
D
H
Weight
Remote controller
Control voltage (by built-in transformer)
Notes : Test conditions are based on ARI 210/240
Rating conditions (cooling) — Indoor : 80˚FDB, 67˚FWB, Outdoor : 95˚FDB, (75˚FWB) Rated frequency : 60Hz
1 :

Operating Range

Maximum
Cooling
Minimum
Model
V, phase, Hz
A
A
F.L.A
CFM
pt./h
dB(A)
in.
in.
in.
in.
Ib.
Indoor intake air temperature
95˚FDB, 71˚FWB
67˚FDB, 57˚FWB
MS-A09WA
MS-A09WA
1.2
0.95
335(300)-261(233)-183(162)
2.7
26-32-40
23
Wireless type
Outdoor intake air temperature
115˚FDB
67˚FDB
5
MS-A12WA
MS-A12WA
White
115, 1, 60
15
1.2
0.95
406(363)-286(254)-222(198)
3.2
33-38-45
5/8
30-11/16
8-1/4
11-3/4
23
115V AC

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ms-a09wa-1Ms-a12waMs-a12wa-1

Table of Contents