3-1. SPECIFICATIONS
Model
Power source
Cooling capacity
*1
BTU/h
*1
kW
Power input
kW
Current input
A
Heating capacity
*2
BTU/h
*2
kW
Power input
kW
Current input
A
External finish
External dimension
inch
H × W × D
mm
Net weight
lbs (kg)
Heat exchanger
Water volume
L
FAN
Type × Quantity
External static
in.WG
press.
Pa
Motor type
Motor output
kW
Driving mechanism
Airflow rate
cfm
(Low-Mid2-Mid1-High)
K/min
L/s
Sound pressure level
(Low-Mid2-Mid1-High)
dB <A>
(measured in anechoic room)
Insulation material
Air filter
Protection device
Refrigerant control device
Connectable HBC controller
Water
Connection
Inlet
mm O.D.
size
piping
Outlet mm O.D.
diameter
Field pipe
Inlet
mm I.D.
*3,*4
size
Outlet mm I.D.
Field drain pipe size
inch (mm)
Drawing
External
Wiring
Refrigerant cycle
standard
Document
attachment
Accessory
Optional
Drain pump
parts
External heater adapter
Remarks
Notes:
1. Norminal cooling conditions
Indoor: 80°FD.B./67°FW.B. (26.7°D.B./19.4°CW.B.), Outdoor: 95°FD.B. (35°CD.B.)
Pipe length: 25 ft. (7.6 m), Level difference: 0 ft. (0 m)
2. Norminal heating conditions
Indoor: 70°FD.B. (21.1°C.B.), Outdoor: 47°FD.B./43°FW.B. (8.3°CD.B./6.1°CW.B.)
Pipe length: 25 ft. (7.6 m), Level difference: 0 ft. (0 m)
3. Be sure to install a valve on the water inlet/outlet.
4. Install a strainer (40 mesh or more) on the pipe next to the valve to remove the foreign matters.
TCH122
PKFY-WL04NLMU-E.TH PKFY-WL06NLMU-E.TH PKFY-WL08NLMU-E.TH PKFY-WL12NLMU-E.TH PKFY-WL15NLMU-E.TH
4,000
6,000
1.2
1.8
0.02
0.03
0.20
0.25
4,500
6,700
1.3
2.0
0.01
0.02
0.15
0.20
11-25/32 × 30-7/16 × 9-11/32
299 × 773 × 237
24 (11)
0.6
117 - 134 - 145 - 159 141 - 177 - 212 - 247 141 - 191 - 247 - 297 222 - 268 - 318 - 367 226 - 290 - 353 - 420
3.3 - 3.8 - 4.1 - 4.5
4.0 - 5.0 - 6.0 - 7.0
55 - 63 - 68 - 75
67 - 83 - 100 - 117
22 - 26 - 28 - 30
22 - 28 - 33 - 36
Mount board, Screw, Felt tape, L-shape connection pipe,
I-shape connection pipe, Insulation, Tie band
* Details on foundation work, duct work, insulation work, electrical wiring, power source switch, and other
items shall be referred to the Installation Manual.
* Due to continuing improvement, above specifications may be subject to change without notice.
1-phase 208/230 V 60Hz
8,000
2.3
0.04
0.35
9,000
2.6
0.03
0.30
Plastic, MUNCELL (0.7PB 9.2/0.4)
Cross fin (Aluminum fin and copper tube)
0.7
Line flow fan × 1
0
0
DC motor
0.030
Direct-driven
4.0 - 5.4 - 7.0 - 8.4
67 - 90 - 117 - 140
22 - 30 - 36 - 41
Polyethyene sheet
PP honeycomb
Fuse
CMB-WP-NU-AA, CMB-WP-NU-AB
22
22
20
20
I.D. 5/8 (16)
VK01B214
VG79N339
Installation Manual, Instruction Book
PAC-SK01DM-E
PAC-YU25HT
4
12,000
15,000
3.5
4.4
0.05
0.45
13,500
17,000
4.0
5.0
0.04
0.40
11-25/32 × 35-3/8 × 9-11/32
299 × 898 × 237
29 (13)
1.0
1.1
6.3 - 7.6 - 9.0 - 10.4 6.4 - 8.2 - 10.0 - 11.9
105 - 127 - 150 - 173 107 - 137 - 167 - 198
29 - 34 - 38 - 41
30 - 36 - 41 - 45
Unit converter
Btu/h = kW × 3,412
cfm = m³/min × 35.31
lb = kg/0.4536
*Above specification
data is subject to
rounding variation.

Advertisement

Table of Contents
loading

Table of Contents