Mitsubishi Electric MS-A09WA Service Manual page 32

Indoor unit wireless type air conditioner
Hide thumbs Also See for MS-A09WA:
Table of Contents

Advertisement

(5) TEMPERATURE buttons
In "I FEEL CONTROL" (
In addition, set temperature can be controlled by TOO WARM or TOO COOL buttons when you feel too cool or too warm.
Each time the TOO WARM or TOO COOL button is pressed, the indoor unit receives the signal and emits a beep tone.
Fuzzy control
When the TOO COOL or TOO WARM button is pressed, the microprocessor changes the set temperature, considering
the room temperature, the frequency of pressing TOO COOL or TOO WARM button and the user's preference to heat or
cool. So this is called "Fuzzy control", and works only in "I FEEL CONTROL" mode.
In DRY mode of "I FEEL CONTROL", the set temperature doesn't change.
TOO
COOL
... To raise the set temperature 2~4 degrees (°F)
TOO
WARM
... To lower the set temperature 2~4 degrees (°F)
11-5. AUTO VANE OPERATION
1. Horizontal vane
(1) Vane motor drive
These models are equipped with a stepping motor for the horizontal vane. The rotating direction, speed, and angle of
the motor are controlled by pulse signals (approx. 12V) transmitted from indoor microprocessor.
(2) The horizontal vane angle and mode change as follows by pressing VANE CONTROL button.
(3) Positioning
The vane is once pressed to the vane stopper to confirm the standard position and then set to the desired angle.
Confirming of standard position is performed in the following cases.
(a) When the operation starts or finishes (including timer operation).
(b) When the test run starts.
(c) When multi-standby starts or finishes.
(4) VANE AUTO (
) mode
In VANE AUTO mode, the microprocessor automatically determines the vane angle and operation to make the optimum
room-temperature distribution.
In COOL, DRY and FAN operation
(5) STOP (operation OFF) and ON-TIMER standby
In the following cases, the horizontal vane returns to the closed position.
(a) When OPERATE/STOP (ON/OFF) button is pressed (POWER OFF).
(b) When the operation is stopped by the emergency operation.
(c) When ON-TIMER is ON standby.
(6) Dew prevention
During COOL or DRY operation with the vane angle at Angle 2 ~ 4 when the compressor cumulative operation time
exceeds 1 hour, the vane angle automatically changes to Angle 1 for dew prevention.
(7) SWING MODE (
By selecting SWING mode with VANE CONTROL button, the horizontal vane swings vertically. The remote controller
displays "
" .
) mode, set temperature is decided by the microprocessor based on the room temperature.
Upward
)
Vane angle is fixed to Horizontal position.
32

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ms-a09wa-1Ms-a12waMs-a12wa-1

Table of Contents