3.1 Key Inputs
A key input becomes valid after 40 ms, to eliminate chatter.
The ATT.THROUGH key input from OFF to ON becomes valid
when the key is held pressed for 2 seconds.
3.2 Switch inputs
The MODE switch (rotary switch) setting is read when the power is
turned on.
The switch operation with POWER ON is invalid.
(See "7. WARNING."(P.50))
4. KEY PROCESSING (IC901)
4.1 ATT.THROUGH Switching
The ATT.THROUGH key input from ON to OFF becomes valid
when the key is held pressed for 2 seconds.
Any other key input during these 2 seconds is invalid.
When switching from OFF to ON, the key input becomes valid at
normal timing.
EEPROM writing
Relay
Mute
LED ON/OFF
processing
Switching
VOL. processing
(ON → OFF)
VOL. data line processing
(OFF → ON)
Silent processing
Key input valid
1
2
10 msec
4
40 msec
5
2 sec
6
40 msec
7
100 msec
8
2 sec
9
Fig.2 Timing chart when ATT. through key is pressed
Port 16 (SPRYH)(Pin16) is set to "L" 10 ms after ATT.THROUGH
switching signal input, and relay is set to OFF.
After another 30 ms, the INDICATOR port is processed.
Port 31 (FMT)(Pin31) is set to "H," and muting is set to ON.
Switching process is performed 100 ms after ATT.THROUGH
switching signal input.
When switching ATT THROUGH from ON to OFF:
Data transfer to the DAC IC is performed 2 seconds after the key
input.
When switching ATT.THROUGH from OFF to ON:
Port 2 (LD), port 3 (CLK), and port 4 (SRD) are fixed to "L" before
DACVR (pin 13) is set to "L," 30 ms after relay becomes OFF.
(See "6. DAC Volume Transfer."(P.49))
After another 2 seconds, port 31 (FMT)(Pin31) is set to "L," and
muting is set to OFF.
After another 3 seconds, port 16 (SPRYH)(Pin16) is set to "H," and
relay becomes OFF.