TH-47LFT30W
8.26. How to replace the airflow sen-
sor
Two airflow sensors are placed in the positions shown in the
drawing. Take the following steps to replace the airflow sen-
sors.
1. Remove the cover-fan-side assembly.
2. Undo the screws shown in the drawing to remove the air-
flow sensors together with the holder. (SCR BIN+SW+W
4X10)
3. Undo the screws shown in the drawing to remove the air-
flow sensors. (SCR BIN+SW+W 3X12)
4. Replace them with the replacement airflow sensors.
8.27. How to replace the Panasonic
badge
* The Panasonic badge is attached to the replacement cab-
inet front, but the Panasonic badge itself can be also sup-
plied as a single part. Take the following steps to replace
the Panasonic badge.
1. Detach the Panasonic badge
2. Attach the replacement Panasonic badge to the specified
position on the cabinet front as shown in the drawing.

8.28. How to replace the gaskets

The gaskets are fitted in the following positions of this unit.
When replacing any parts around them, stick the replacement
gasket together before putting them in place.