3. For leaving the plasma panel from the front frame, pull the
bottom of the front frame forward, lift, and remove.
6.30. Replace the plasma panel
(finished).
1. Place the new plasma panel (finished) on the flat surface of
the table (covered by a soft cloth), with the plasma panel
surface facing downward.
2. Attach the C1, C2, C3, C4 and C5-Board and the C6-Board,
connect the flexible cables (×7) from the Plasma panel to
the C1, C2, C3, C4 and C5-Board and C2-Board, and fix
the flexible cable holders.
3. Attach the Hooks (left, right) and fit the stand brackets (left,
right) to the new plasma panel.
4. Place the plasma panel section on the servicing stand.
5. Attach the front frame and the each P.C.Board and so on,
to the new plasma panel.
* When fitting the front frame, be careful not to allow
any debris, dust or handling residues to remain
between the front glass and plasma panel.