Icom IC-F50 Service Manual Addendum page 36

Hide thumbs Also See for IC-F50:
Table of Contents

Advertisement

5-2 SOFTWARE ADJUSTMENTS (TRANSMITTING)
Select an operation using [↑] / [↓] keys, then set specified value using [←] / [→] keys on the connected computer keyboard.
ADJUSTMENT
PLL LOCK
1 • Operating CH
VOLTAGE
• Receiving
[LV (RX LVA)]
2 • Operating CH
[LV (TX LVA)]
• Transmitting
3 • Operating CH
• Receiving
4 • Operating CH
• Transmitting
REFERENCE
1 • Operating CH
• Connect an RF power meter or 50 Ω
FREQUENCY
[REF]
dummy load to the antenna connector.
• Transmitting
OUTPUT
1 • Operating CH
POWER
• Transmitting
[Power (Hi)]
[Power (L2)]
2 • Operating CH
• Transmitting
[Power (L1)]
3 • Operating CH
• Transmitting
FM
1 • Operating CH
DEVIATION
• Set the FM deviation meter as:
[MOD N]
HPF
(Narrow)
LPF
De-emphasis : OFF
Detector
• Connect the audio generator to the multi
connector through the JIG cable (*OPC-966)
and set as:
• Transmitting
[MOD Ratio]
2 • Operating CH
(Middle; [IC-F51] only)
• Transmitting
[MOD Ratio]
3 • Operating CH
(Wide)
• Transmitting
MODULATION
1 • Operating CH
BALANCE
• No audio applied to the multi connector.
[BAL N]
• Set an FM deviation meter as:
(Narrow)
HPF
LPF
De-emphasis : OFF
Detector
• IF bandwidth
• Transmitting
[BAL Ratio]
2 • Operating CH
(Middle; [IC-F51] only)
• Transmitting
[BAL Ratio]
3 • Operating CH
(Wide)
• Transmitting
CTCSS/DTCS
• Operating CH
DEVIATION
• No audio applied to the multi connector.
[CTCS/DTCS]
• Transmitting
ADJUSTMENT CONDITION
: CH1
: CH1
: CH10
: CH10
: CH1
: CH2
: CH3
: CH1
: CH4
: OFF
: 20 kHz
: (P–P)/2
: 1.0 kHz/150 mVrms
: CH5
: CH6
: CH1
: OFF
: 20 kHz
: (P–P)/2
: Narrow
: CH7
: CH8
: CH9
MEASUREMENT
UNIT
LOCATION
Soft
Check the "RX LV" item on the
ware
CS-F50 ADJ's screen.
Check the "TX LV" item on the
CS-F50 ADJ's screen.
Soft
Check the "RX LV" item on the
ware
CS-F50 ADJ's screen.
Check the "TX LV" item on the
CS-F50 ADJ's screen.
op
Loosely couple a frequency
panel
c o u n t e r t o t h e a n t e n n a
connector.
Top
Connect an RF power meter to
panel
the antenna connector.
Top
Connect an FM deviation
panel
meter to the antenna connector
through the attenuator.
Connect an FM deviation meter
with an oscilloscope to the
antenna connector through an
attenuator.
Top
Connect an FM deviation
panel
meter to the antenna connector
through the attenuator.
5 - 4
VALUE
3.5 V
3.5 V
0.9–1.5 V
(Verify)
0.9–1.5 V
(Verify)
174.0000 MHz
±300 Hz
5.0 W
1.0 W [EUR-88]
2.0 W
1.0 W [EUR-88]
1.0 W
±2.05 to ±2.15 kHz
±3.15 to ±3.25 kHz
±4.05 to ±4.15 kHz
Set to square wave
form
±0.66 to ±0.70 kHz

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ic-f51

Table of Contents