Available Replacement Parts For Your Machine
Refer to the following diagram if you need to order basic replacement parts for your machine.
Do not use replacement parts other than those available through Rug Doctor. Do not attempt
repairs on a machine under warranty.
10460
10461 Lower Tank
Dome Filter
Sump Filter
93084 Recovery
60400 Lower Tank
Bucket
Replacing A Brush
1. The brush strip is held in place by a snap fit connection.
2. Remove the old brush strip by pulling down on the plastic brush body.
3. Insert the new brush strip until it is fully seated.

Troubleshooting

Use this section to help resolve any issues you experience with your machine. If you do not
find the answer to your questions here, please contact the Rug Doctor Hotline at
1-800 RUG DOCTOR (1-800-784-3628) or through the Rug Doctor web site at RugDoctor.com.
The Rug Doctor Hotline is available 7 days a week (except on legal holidays) from
8 am to 8 pm (CST).
Power Issues
Always use a grounded outlet with this machine. Not doing so can result in electrical shock.
Refer to the Grounding Instructions section for more
The machine switch is on, but there is no power.
Try the following:
• Make sure the electrical cord is plugged in. If the electrical outlet is connected to a wall switch, make sure the wall
switch is in the ON position.
• Check the circuit breaker switch on the machine and reset if necessary.
• Check the ALCI plug and reset if necessary.
• Check the wall circuit breaker. If it is off or if a fuse is blown, unplug the machine and reset the circuit breaker or
replace the fuse. Plug the machine into a different wall plug before beginning again.
• Check the power cord. If it is defective, please contact the manufacturer or an authorized service agent.
An authorized professional must repair the machine.
The machine switch is on, but there is intermittent power.
Please contact the manufacturer or an authorized service agent. Faulty electrical cable,
defective switches, or loose terminal connections can cause intermittence. An authorized
professional must repair the machine.
Vacuum Issues
Try the following:
• Make sure the dome hood is closed and securely sealed.
• Check the hose connection at the back of the machine and secure if necessary.
• Clean the filter that is in the dome.
• Remove any accumulated debris around the vacuum slot.
If none of the above steps fix the problem, the vacuum hose assembly inside the machine may be defective.
Contact the manufacturer or an authorized service agent. An authorized professional must repair the machine.
20091 Screw, #8 X 1/2"
(For lower tank Fill Filter)
60778 Wheel
Fill Filter
60779 Brush Strip
information.