Toshiba RAV-103TUH-PE Service Manual page 9

Toshiba rav-103tuh-pe; rav-133tuh-pe; rav-132ah-pe; rav-163tuh-pe; rav-162ah-pe air conditioner split type
Hide thumbs Also See for RAV-103TUH-PE:
Table of Contents

Advertisement

3.2 RAV-132AH-PE
RAV-162AH-PE
F
2
20SF
Power Supply 220/240V
1.
Shows terminal block and figures show terminal numbers.
Broken lines show wiring at site.
Don't operate the units with magnetic contactor pushed.
Symbol
Name
20SF
Solenoid Coil (4 Way Valve)
RY05, 07 Relay
51C
Overload Relay
20SR
Solenoid Coil (2 Way Valve)
RCc
Running Capacitor (Compressor)
RCo
Running Capacitor (Fan motor)
Earth
Screw
Earth
RY05
F
RY07
BLK
WHI
52C
26HD
20SR
50Hz
Symbo
CM
Compressor
52C
Magnetic Contactor
FMo
Fan Motor (Out door)
TL
Sensor
TE
Sensor
26HD Bimetal Thermostat
WHI
63H
GRY
52C
Name
-9-
Indoor unit
Outdoor unit
TR
RED
TD
Wave
Control
BLK
Circuit
BLU
RED
BLK
BLK
RED
RED
FM
WHI
WHI
0
RC
O
CM
RC
C
51C
CH
Symbol
Name
F2
Fuse (T5A)
63H
High Pressure Switch
CH
Crank Case Heater
F
Fuse (on PCB)
TR
Transformer
TD
Sensor
TE
TL