  • Page 1 MTBE FILTRATION SYSTEM MODEL US-1000 INSTRUCTION MANUAL ©2013 Pentair Residential Filtration, LLC www.pentairaqua.com...
  • Page 2: Tools And Materials Required

    SPECIFICATIONS Date the bottom of any new or replacement housing to indicate the next recommended Temperature Range: 40–100°F (4.4–37.8°C) replacement date. Pressure Range: 30–125 psi (2.1–8.62 bar) NOTE: Service Flow Rate @ 60 psi (4.1 bar): 0.5 gpm (1.9 L/min) • For cold water use only.
  • Page 3 PENTEK • 3 US-1000 MTBE Filtration System Instruction Manual ®...
  • Page 4: Installation

    INSTALLATION • F or standard under-sink installation on 1/2" 14 NPS threads (most common thread on kitchen faucets) cold water line. • P lease read all instructions and precautions before installing and using your MTBE Filtration System. • Numbered diagrams correspond with numbered steps. 1. Installing the Water Supply Adapter The supply adapter fits 1/2"-14 NPS supply threads. If local codes permit, it may be used to connect the US-1000 to the cold water supply line.
  • Page 5: Mounting The System

    (C) From under the sink, slide the metal washer on and thread on the wing nut. Tighten the wing nut by hand until tight. It may be necessary to have a second person to hold the faucet while tightening the wing nut. NOTE: Do not overtighten the wing nut.
  • Page 6: Connecting The System

    7. Connecting the System (A) Assemble tubing with system as shown in Fig. 7A, inserting tubing into appropriate inlet or outlet quick-connect fitting until it stops. NOTE: In some installations, connecting the system to the water supply adapter and/or drinking water faucet causes the tubing to enter the quick-connect fitting at a sharp angle.
  • Page 7: Filter Cartridge Replacement

    FILTER CARTRIDGE REPLACEMENT TROUBLESHOOTING • F ilter cartridges the US-1000 will last about 500 gallons or Leaks: six months before they need to be replaced. Filter cartridge life varies depending on usage, and/or water conditions..between cap and bottom of filter housing Changes in taste, color, and flow of the water being filtered Turn off water supply valve and turn on drinking water faucet to indicate that the cartridge should be replaced.
  • Page 8 5. If flow through empty system is adequate, place one filter cartridge in system at a time and check flow to make sure State of California cartridge is not clogged. Replace clogged cartridge if Department of Public Health necessary. Water Treatment Device Certificate Number 04 - 1687...
  • Page 9: Replacement Parts

    REPLACEMENT PARTS Test Conditions Flow Rate = as noted for filter system 155832-44 P-250A (Cartridges sold only as a set) Inlet Pressure = 60 psi (4.1 bar) 153126 White housing = 7.5±1 151231 O-ring (OR-233) Temperature = 68°F ± 5°F (20°C ± 2.5°C) 244960 * Lead-Free Faucet Operating Requirements...
  • Page 10 10 • PENTEK US-1000 MTBE Filtration System Instruction Manual ®...
  • Page 11 PENTEK • 11 US-1000 MTBE Filtration System Instruction Manual ®...
  • Page 12 All Pentair trademarks and logos are owned by Pentair, Inc. or its affiliates. All other registered and unregistered trademarks and logos are the property of their respective owners. Because we are continuously improving our products and services. Pentair reserves the right to change specifications without prior notice.