Dead machine service check

CAUTION: Check the AC line voltage. The voltage should be within the following limits:
FRU
LVPS/HVPS

Fuser service check

When toner is partially fused to the media, it is usually caused by low fuser temperature.
The line voltage to the printer must be within the following limits:
100 V ac–127 V ac for the 110 V model printer
200 V ac–240 V ac for the 220 V model printer
This printer uses a belt fuser and therefore does not have a lamp.
Fuser service check
FRU
Fuser power cable
LVPS/HVPS
Fuser
Fuser
100 V ac (volts alternating current) – 127 V ac for the 110 V printer
200 V ac – 240 V ac for the 220 V printer
Action
Unplug the printer. Remove the LVPS/HVPS, and check the fuses for continuity.
• If open, replace the LVPS/HVPS.
• If not open, check the switch continuity across its conductors with the switch on. Turn
the switch off. Plug the AC line into the LVPS/HVPS and switch unit on.
Note: Voltages may be exposed at several places on the board. Do these verifications, and
then unplug the card:
Verify 24 V dc on pins 8, 9, and 10 at PCN1.
Verify approximately 3V on pins 1–3.
Verify approximately 5V on pins 4 and 13.
If voltages are not correct, replace the LVPS/HVPS.
If voltages are correct, check the controller card. See
service check" on page
Action
Unplug the printer, and disconnect the fuser cable plug from the LVPS/HVPS board
connector at PCN5.
Check for continuity across the fuser by checking across the connector pins.
• If there is continuity, check the LVPS/HVPS. See
page
2-20.
• If there is no continuity, disconnect the fuser power cable at both ends and check each
conductor for continuity. Replace cable if necessary.
• If the cable tests good, replace the fuser.
Make sure the fuser thermistor is correctly connected to the controller board at J13. If the
problem persists, disconnect the thermistor cable and check for less than +5 V dc on pin 1.
Pin 2 should be ground. If line voltage is incorrect on pin 1, see
check" on page 2-17
for more information.
Disconnect the thermistor cable from J13 on the controller card.
Measure the resistance across the ends of the thermistor cable.
Replace the fuser assembly if the resistance is lower than 1K ohm or shorted.
Note: Resistance measures approximately 400K ohms when cool and 1K ohms hot.
2-17.
"LVPS/HVPS service check" on
"Controller card service
Diagnostics information
4512-420, -430
"Controller card
2-19