Sequence draining with pressure switch level check
drain pump
Drain Cycle
First draining before every wash cycle
Draining after the wash cycles
New draining with sequence draining
-
The draining step contains of 3 time sequences.
In the middle sequence, during time T2 the drain pump is stopped.
-
At the end of the drain step, the water level is checked.
-
If the switch back is reached, the drain step is terminated.
If the switch back isn't reached, the drain step is repeated.
-
A failure code is displayed, if after 2 drain steps, the switch
back couldn't be reached.
In this case, the program is stopped.
1 dr aining sequence
with variable timing
on
off
T1
(variable)
.
level c heck!
T2
T3
(variable)
(variable)
T1
T2
45 sec
15 sec
30 sec
20 sec
19
T3
20 sec
10 sec