Electrolux EDW 1003 Service Manual page 19

Table of Contents

Advertisement

Sequence draining with pressure switch level check
drain pump
Drain Cycle
First draining before every wash cycle
Draining after the wash cycles
New draining with sequence draining
-
The draining step contains of 3 time sequences.
In the middle sequence, during time T2 the drain pump is stopped.
-
At the end of the drain step, the water level is checked.
-
If the switch back is reached, the drain step is terminated.
If the switch back isn't reached, the drain step is repeated.
-
A failure code is displayed, if after 2 drain steps, the switch
back couldn't be reached.
In this case, the program is stopped.
1 dr aining sequence
with variable timing
on
off
T1
(variable)
.
level c heck!
T2
T3
(variable)
(variable)
T1
T2
45 sec
15 sec
30 sec
20 sec
19
T3
20 sec
10 sec