  • Page 2: Declaration Of Conformity

    Declaration of Conformity (As referred to in Annex IV 2. of Directive 2004/108/EC) Declares under his sole responsibility that the produced manufactured by Digital Broadband Sonar Koden Electronics Co., Ltd. 5278 Uenohara Uenohara-Shi Yamanashi-Ken 409-0112, Japan Telephone +81 554 20 5865...
  • Page 3 Koden Electronics Co., Ltd. The technical descriptions contained in this publication are subject to change without notice. Koden assumes no responsibility for any errors, incidentals or consequential damages caused by misinterpretation of the descriptions contained in this publication.
  • Page 4: Important Notice

    Koden is needed. Koden prohibits the un-authorized copy and transcription of this manual. • If this manual is lost or damaged, consult a dealer of Koden or Koden. • The specification of the products and the contents in this manual are subject to change without notice.
  • Page 5 When the inside is to be checked, ensure to switch off the power and to discharge the residual voltage for safety. An engineer authorized by Koden shall carry out the inspection and maintenance works.
  • Page 6 In case of failure, please Warning contact Koden’s dealers or Koden. In case of smoking or firing, switch off the power in the boat and of this equipment. It may lead to firing, electric shock or damages.
  • Page 7: Table Of Contents

    KDS-6000BB Contents Contents Document Revision History ..................... i Important Notice ........................ii For Your Safe Operation ......................iii Contents ..........................v Introduction .......................... viii System Configuration ......................ix Configuration of Equipment ....................x Basic knowledge for making use of sonar ................xv Chapter 1 Preparation .....................1-1...
  • Page 8 Contents KDS-6000BB 2.2.11 Color rejection ........................ 2-11 2.2.12 Sub-screen selection ...................... 2-12 2.2.13 Sub-screen display ......................2-13 2.2.14 Language ........................2-13 Menu2 ........................2-15 2.3.1 Step (Sonar, Off-center) ....................2-16 2.3.2 Step (Bottom-scan) ......................2-16 2.3.3 Off-center position ......................2-17 2.3.4...
  • Page 9 KDS-6000BB Contents Chapter 3 Operation keys ..................3-1 To use keys ......................3-1 3.1.1 Presentation mode key ....................3-1 3.1.2 Range key ........................3-1 3.1.3 Sector key ........................3-2 3.1.4 Gain key ........................... 3-2 3.1.5 TVG key ........................... 3-3 3.1.6 Power/Panel brightness key .................... 3-4 3.1.7...
  • Page 10 This unit equipped with the latest digital process can accurately display circumstances in the water under all conditions. KDS-6000BB is the Black Box type without the display unit, for which customer can select the display monitor of preference. The external monitor and connecting cable are user supply.
  • Page 11: System Configuration

    KDS-6000BB System Configuration System Configuration Connection Diagram Legend Standard DOU-620 Operation Option unit DOU-620R Owner supply (with RCW-14) CW-412-5M J7 (16P) Remote controller J1 (5P) RCW-14 Onboard DC CW-259-2M POWER (3P) J5 (10P) power supply Processor unit DPU-610 10.8 to D-sub15P 31.2VDC...
  • Page 12 12p pin water resistant c connector Fuse F-7161-10A/ /N30C-125 Normal fu usion type f main pow Cylinder (ø 6 6.4x30) Opera ation manua KDS-6000BB B.OM.E English Quick k Reference KDS-6000BB B.QR.E English Instal lation manu KDS-6000BB B.IM.E English 00931600...
  • Page 13 KDS-6000BB Configuration of Equipment b. TD tank / TD shaft Weight/ Name of item Type Remark Length TD tank ESR-1506 (PVC) 1230mm Select 9.0kg 30927C-2 (PVC) 1500mm according to 11.0kg 30927C-3 (PVC) 1800mm equipment. 13.0kg ESR-1507 (FRP) 1500mm *Refer to 12.0kg...
  • Page 14 Configuration of Equipment KDS-6000BB Package 2 Weight/ Name of item Type Remark Length Crank handle OB-03 Grease 100g Fuse F-7161-4A At input of EACH 12 V F-7161-8A At input of 24 V ANP base ANP-1 Binding Band AB-100-1000 Package 3...
  • Page 15 S-6000BB Configu uration of E Equipment Pack kage 4 Weight/ me of item Type mark Length Transduce er unit U-6302 9.0kg With 10 m cable (With 18 8P water resistan nt and one end d plain) Bath cork Bath cork (White e) 50g Caution: D Don’t carry...
  • Page 16 Configuration of Equipment KDS-6000BB Option List Name of item Type Remark Remote controller RCW-14 With 5m cable, (with Operation unit) TD tank ESR-1506 PVC, 1230mm (For 1411mm of TD shaft) (For *xxxx mm of TD 30927C-2 PVC, 1500mm (For 1681mm of TD shaft)
  • Page 17 S-6000BB Basic know wledge for making us se of sonar sic know wledge fo or making g use of sonar We s suppose tha at you, the user of son nar, already y know how w to use son nar. In this section we will th heorize you...
  • Page 18 Basic knowledge for making use of sonar KDS-6000BB Surface layer: This layer is greatly affected by the natural phenomena (e.g., sun, wind, rain, etc.) since it is adjacent to the atmosphere. Besides, the propagation route of ultrasonic wave refracts on the boundary where the temperature variations in addition to the difference in temperature between daytime and night are the greatest depending on the temperature distribution.
  • Page 19 (In order to reduce this failure, KDS-6000BB provides a built-in stabilizer function.) (3) Reduction of gain due to traveling noise Noises produced by the engine rotation, propeller rotation, and the friction between the ship’s hull and sea water are mixed into echoes to reduce the detecting gain of echoes.
  • Page 20: Chapter 1 Preparation

    S-6000BB hapter 1 P Preparation Chapt ter 1 Pr reparati 1.1 T To use key Operati ion unit of KDS-6000B (12) (15) (10) (11) (17) (18) Key Name Description [Power/P Panel brigh tness] Press: Po ower on. Ad djust brillian nce of Ope eration unit (panel brig...
  • Page 21 Chapter 1 Preparati KDS-60 00BB Press s: Change o of TVG sett ting [Til Press s: Change o of the tilt an ngle ector] Press s: Change o of the scan sector enu] Press s: Open/Clo ose/Switch the menu nob/left] Turn :Change the e setting ite...
  • Page 22 S-6000BB hapter 1 P Preparation Norm mal operatio on is done w with [Press]. n the relev ant key is l ong-presse ed, the men nu box of th he function defined for r the key is disp played. Rele ease the fin nger from th he key, once...
  • Page 23 Chapter 1 Preparati KDS-60 00BB 1.2 Power r On/Off 1.2.1 Pow wer On Press to pow er on. The start-u up screen is displaye ed. On star rt-up, the i nternal me mory (ROM M and RAM M) is automatica ally checke d.
  • Page 24: Power Off

    S-6000BB hapter 1 P Preparation 1.2.2 2 Power O Keep p pressing 3 seconds t to power of ff. After coun ntdown for power shut down, when n the messa age of [Pre eparing for t the end] an nd the indica ation below w is displaye ed, release...
  • Page 25 Chapter 1 Preparati KDS-60 00BB 1.4 To use e Menu KDS-6000 BB has thre ee kinds of menu; [Men nu1], [Menu u2] and [Me nu3]. 1.4.1 Ope en/Close th he Menu To display the menu, press Each time pressed, [M Menu1] / [Me enu2] / [Me nu3] are sw...
  • Page 26 S-6000BB hapter 1 P Preparation Name of th he selected s setting item in red color r box Setting item m box etting value b enu1 Freq select 130.0 Dynamic range 26 dB Pulse width Middle TX power Auto Color rejection Noise rejection Color mage correct...
  • Page 27 00BB 1.5 Adjus stment of b brilliance 1.5.1 Adju ustment of f LCD brillia ance Caut tion: For K KDS-6000BB B the scree en brillianc ce cannot b be adjusted d by pressing . Ple ease adjus st brilliance e by the LC CD monitor' operation.
  • Page 28: Screen Display

    KDS-6000BB Chapter 1 Preparation 1.6 Screen display The screen data presentation system is as follows. The KDS-6000BB offers a variety of display modes in split screen by combination of Mode dials and Menu. Split screen left Split screen right [Sonar]...
  • Page 29: Sonar Mode Display

    Direction/Distance Time Information- Data display Range Bearing center Sector Tilt Gain VRM1 (Range marker, Bearing marker) VRM2 (Cross cursor) Caution: To present this info will require Bearing the KDS-6000BB is connected to an Speed external navigator. Ship’s position 1-10 0093160002-00...
  • Page 30: Sonar Mode Operation

    KDS-6000BB Chapter 1 Preparation 1.6.2 Sonar mode Operation The Transducer unit sends out a beam of ultrasonic sound which sweeps in the specified sector and bearing. The echoes of reflected sound waves are picked up by the Transducer unit and displayed like a radar in their respective range and direction on the Display unit screen.
  • Page 31 Chapter 1 Preparation KDS-6000BB The tilt angle can be changed from 5° above horizontal to -90° vertical in a 1° step. 5゜ ・With this range all dorections from extremely 0゜ shallow waters to deep areas may be searched. ・When adjusting the tilt angle please consider the Tilt angle 俯角可変範囲...
  • Page 32: Bottom-Scan Mode Display

    (Depth, Direct distance, Horizontal distance from the intersection of the Depth marker and the side marker.) VRM2 (Depth, Direct distance, Horizontal distance from the cross cursor) Bearing Caution: To present this info will require Speed the KDS-6000BB is connected to an Ship’s position external navigator. 0093160002-00 1-13...
  • Page 33: Bottom-Scan Mode Operation

    Chapter 1 Preparation KDS-6000BB 1.6.4 Bottom-scan mode operation The sonar beam sweeps from side to side undernearth the vessel. The screen will clearly display echoes from the middle depth and sea-bottom contour. ・The ultra sonic sound beams out as the beam sweeps from side to side.
  • Page 34: Echo Sounder Mode Display

    The depth display can be appeard when the tilt angle is set to -90° only. Information- Data display Range Bearing center Sector Tilt Gain Depth display (VRM) Water temp. Bearing Speed Caution: To present this info will require Ship’s position the KDS-6000BB is connected to an external navigator. 0093160002-00 1-15...
  • Page 35: Echo Sounder Mode Operation

    1.6.6 Echo sounder mode operation The sonar beam sweeps underneath the vessel and the KDS-6000BB can be used as echosounder mode by selecting of [Echo sounder] mode of the presentation mode. The screen will clearly display echo sounder images from the middle depth and the sea-bottom contour.
  • Page 36: Chapter 2 Function Setting

    KDS-6000BB Chapter 2 Function setting Chapter 2 Function setting Menu configuration 2.1.1 Initial setting The factory default setting is shown in square. Functions Factory setting (in the item Setting Menu Change at Menu1 Freq select 130, 130.1, 130.2 => 209.8, 209.9, 210...
  • Page 37 Chapter 2 Function setting KDS-6000BB Functions Factory setting (in the item Setting Menu Temperature adjustment -9.9 • • • •0.0 • • • •9.9 Train correct -180.00 => 0.00 => +180.00 (1.25°step) Ext synchronized Off , ↑, ↓ Bearing display...
  • Page 38: Menu1

    S-6000BB Chapte ter 2 Funct tion setting Menu1 To di isplay the m menu, press nd select [M Menu1]. The s selected me enu item wi ll be display yed in red c color box. Ther re are 18 se etting items in [Menu1] box.
  • Page 39 Chapter 2 2 Function setting KDS-60 00BB Menu1 Freq sel lect 130.0 Dynamic c range 26 dB Pulse w idth Middle TX powe Auto Color rej jection Noise re ejection Color Image c correct Gain (TD 3. Press (kno ob/left) or to mo ove setting value box.
  • Page 40: Gain (Td)

    S-6000BB Chapte ter 2 Funct tion setting The setting v value will be e displayed d in red colo or box. Range1 20 m 5. T Turn (knob/left) to select [R Range settin ng value]. Set a as the same e way [Rang ge 2 to Ran nge 8] as ab...
  • Page 41 Chapter 2 2 Function setting KDS-60 00BB Gain (TD) adjustmen When the bottom can nnot be dete ected or wh hen the bott tom is of m ud pool or seaweed, [ [Gain (TD)] shall l be turned up. When transfer to fish schoo ols, etc.
  • Page 42: Pulse Width

    S-6000BB Chapte ter 2 Funct tion setting 3. Pr ress (knob/left) o to m move setting g value box 26 dB Dynamic rang 4. Tu knob/left) to o select the e setting val ue from [12 2dB] to [32d dB]. When the value is s mall, the t...
  • Page 43: Tx Power

    Chapter 2 2 Function setting KDS-60 00BB Short: auto omatically c changes the e transmit p pulse width according t to the range e (normal) l listed belo Middle: au tomatically the normal transmit pu ulse width x x 1.5 A longer pu ulse width p provides hig...
  • Page 44: Noise Rejection

    S-6000BB Chapte ter 2 Funct tion setting 2.2.7 7 FIR (Ban ndwidth) Chan nge the freq quency ban ndwidth. To o avoid the noise, inte rference, e etc., set the frequency band dwith to narr row. 1. Pr ress to be displa ayed [Menu u1].
  • Page 45 Chapter 2 2 Function setting KDS-60 00BB 2. Turn (knob/l left) to selec ct [Noise re eduction]. Menu1 Freq select 130.0 Dyna amic range 26 dB Pulse e width Middle TX po ower Auto Color r rejection Noise e rejection Color Imag e correct...
  • Page 46: Color Selection

    S-6000BB Chapte ter 2 Funct tion setting 4. Tu knob/left) to o select the e setting val ue from [Of ff], [1], [2] or r [3]. [Off]: : No effect [1]: W Weak effect [2]: M Midium effec [3]: S Strong effec 5.
  • Page 47 Chapter 2 2 Function setting KDS-60 00BB 2. Turn (knob/l left) to selec ct [Color rej jection]. Menu1 Freq se elect 130.0 Dynam mic range 26 dB Pulse w width Middle TX pow Auto Color re ejection Noise r rejection Color Image correct...
  • Page 48 S-6000BB Chapte ter 2 Funct tion setting 5. Pr ress to close the menu. 2.2.1 Sub-sc creen displ Sub- -screen disp play can be selected fro rom [Off], [S Small] and [L Large]. 1. Pr ress to be displa ayed [Menu u1].
  • Page 49 Chapter 2 2 Function setting KDS-60 00BB Menu1 Auto Range e (Sonar, Off-ce enter) Range e (Bottom-scan) Range e (Echo sounde Remo ote key set Wake disp (H Sub-s screen selection Sub-s screen display Wake range (Sub-scr reen) 1. 0 Langu uage English...
  • Page 50 S-6000BB Chapte ter 2 Funct t ion setting Menu2 To di isplay the m menu, press nd select [M Menu2]. The s selected me enu item wi ll be display yed in red c color box. Ther re are 23 se etting items in [Menu2] box.
  • Page 51 Chapter 2 2 Function setting KDS-60 00BB 2.3.1 Ste ep (Sonar, O Off-center) The step a angle (scann ning angle) in the Sona ar mode ma ay be select ted. 1. Press to be displayed [ [Menu2]. 2. Turn (knob/l left) to selec ct [Step (So onar, Off-ce...
  • Page 52 S-6000BB Chapte ter 2 Funct tion setting Menu2 Step (Sonar r, Off-center) 10° Step (Bottom m-scan) 5° Off-center po osition Fore Target lock Reve erse A scope White line Scale Internal buz zer volume NMEA moni itor 3. Pr ress (knob/left) o to m move setting...
  • Page 53 Chapter 2 2 Function setting KDS-60 00BB Menu2 Step (S Sonar, Off-cente 10° Step (B Bottom-scan) 5° Off-cen nter position Fore Target lock Reverse A scop White line Scale Interna al buzzer volum NMEA A monitor 3. Press (knob/ left) or to move s setting valu e box.
  • Page 54 S-6000BB Chapte ter 2 Funct tion setting 3. Pr ress (knob/left) o to m move setting g value box Scale 4. Tu knob/left) to o select the e setting val ue from [Of ff], [1], [2], [3 3], [4], [5] o r [6].
  • Page 55 Chapter 2 2 Function setting KDS-60 00BB 4. Turn (knob/l left) to selec ct the settin ng value from m [Off] or [O On]. S W 方 位 Direc ctions を E 表 示 N [Off]: displa ays no poin nts of the co ompass.
  • Page 56 S-6000BB Chapte ter 2 Funct tion setting G line 365° 船首 線 aring display 船 船首方位表示 [Off] : displays n o bearing. [Sma all] or [Large e]: displays t he bearing ( (in small cha aracters or i n large char racters).
  • Page 57 Chapter 2 2 Function setting KDS-60 00BB [Off]: disp plays no wa ke (trackline [On]: disp plays the wa ake (tracklin ne). 5. Press to clos se the menu 2.3.8 Wa ake memory y interval The track i s saved into o memory a and its inter rval can be...
  • Page 58 S-6000BB Chapte ter 2 Funct tion setting 2.3.9 9 True / Re elative bea aring Selec ct the curso or display m mode when a an external navigation equipment t is connecte 1. Pr ress to be displa ayed [Menu u2].
  • Page 59 Chapter 2 2 Function setting KDS-60 00BB Menu2 Step ( (Sonar, Off-cent ter) 10° Step ( Bottom-scan) 5° Off-cen nter position Fore Target t lock Reverse A scop White line Scale Interna al buzzer volum NMEA A monitor 3. Press (knob b/left) or to mov...
  • Page 60 S-6000BB Chapte ter 2 Funct tion setting ・Wh hen Mode2 2 is selecte ed as a tar rget lock m mode, the s sonar beam m will track k the echo autom matically up p and down in addition to the Mod de1 function Mark ker Mode1...
  • Page 61 Chapter 2 2 Function setting KDS-60 00BB : sel ects when t the internal synchroniz zed signal is s used for e external equ uipment. : sele ects when t the rise syn chronized s signal is use ed from ext ernal equip pment.
  • Page 62 S-6000BB Chapte ter 2 Funct t ion setting 2.3.1 Tempe erature unit Temp perature un nit can be se et to °C or ° °F. 1. Pr ress to be displa ayed [Menu u2]. 2. Tu knob/left) to o select [Te mperature unit].
  • Page 63 Chapter 2 2 Function setting KDS-60 00BB 3. Press (knob/ left) or to move s setting valu e box. Tempe erature adjustm ment 4. Turn (knob/l left) to selec ct the settin ng value from m [-9.9] to [ [9.9]. (every y 0.1 steps) 9.9゜...
  • Page 64 S-6000BB Chapte ter 2 Funct tion setting 2.3.1 16 Train co orrect To ad djust the de eviation of th he bow dire ection (0°). In the e Sonar mo ode use to adju ust the Bea ring toward Bow direct tion.
  • Page 65 Chapter 2 2 Function setting KDS-60 00BB 2.3.17 Pow wer freq ad djust To adjust o of swiching frequency o of power su upply. 1. Press to be displayed [ [Menu2]. 2. Turn (knob/l left) to selec ct [Power fr req adjust].
  • Page 66 S-6000BB Chapte ter 2 Funct t ion setting Menu3 To di isplay the m menu, press nd select [M Menu3]. The s selected me enu item wi ll be display yed in red c color box. Ther re are 22 se etting items in [Menu3] box.
  • Page 67 Chapter 2 2 Function setting KDS-60 00BB 2.4.1 Bau ud rate Select the baud rate o of NMEA1 w when extern nal equipme ent is conne ected. 1. Press to be displayed [ [Menu3]. 2. Turn (knob/l left) to selec ct [Baud rat te].
  • Page 68 S-6000BB Chapte ter 2 Funct tion setting 3. Pr ress (knob/left) o to m move setting g value box DBT output 4. Tu knob/left) to o select the e setting val ue from [On n] or [Off]. 5. Pr ress to close the menu.
  • Page 69 Chapter 2 2 Function setting KDS-60 00BB 2.4.4 Me nu time-ou ut period You can se et the Men u time-out period to c close the m enu automa atically from m the last m menu operation. 1. Press to be displayed [ [Menu3].
  • Page 70 S-6000BB Chapte ter 2 Funct tion setting 3. Pr ress (knob/left) move settin ng value bo Hull unit auto u 4. Tu knob/left) to o select the e setting val ue from [Of ff] or [1] to [1 17] (Spped unit:kn).
  • Page 71 Chapter 2 2 Function setting KDS-60 00BB Menu3 ZDA o output Simul ation Menu time-out period Hull u unit auto up Hull u unit operation at the start Transd ducer unit baud d rate 19200 Slow d down the Bearin ng speed Menu (transparent)
  • Page 72 S-6000BB Chapte ter 2 Funct tion setting 3. Pr ress (knob/left) o to m move setting g value box Transducer un nit baud rate 19200 4. Tu knob/left) to o select the e setting val ue from [48 800], [9600] or [19200].
  • Page 73 Chapter 2 2 Function setting KDS-60 00BB Menu3 ZDA o utput Simula ation Menu time-out period Hull un nit auto up Hull un nit operation at the start Transd ducer unit baud rate 19200 Slow d down the Bearin ng speed Menu (transparent) Messa...
  • Page 74 S-6000BB Chapte ter 2 Funct tion setting 2.4.1 11 Sub-scr reen (transp parent) backgroun nd image c can be eas sy to see by changi ng the tra ansparent r ate of the sub-s screen. 1. Pr ress to be displa ayed [Menu u3].
  • Page 75 Chapter 2 2 Function setting KDS-60 00BB Informat tion display 4. Turn (knob/l left) to selec ct the settin ng value from m [Off], [Lat t/long], [Dat te], or [Lat/long g/Date]. [Lat/long]: displays ow wn position and VRM in n numerical l values of l atitude and longitude.
  • Page 76: Dynamic Range

    For example, it is possible to switch the setting for seine fishing to the setting of squid fishing with one touch of a key button. KDS-6000BB is equipped with six [CM] keys, so can be used as if six units of sonars were used at a time.
  • Page 77 Chapter 2 Function setting KDS-6000BB A scope White line Scale Internal buzzer volume NMEA monitor Compass display Wake display Wake memory display 1 Second Sonic speed 0.0% Power freq adjust 250.0 Depth unit Range & Speed unit NM kn Temperature unit °C...
  • Page 78 KDS-6000BB Chapter 2 Function setting Remote key set Hul unit U/D Target lock Marker up Target lock Tilt angle up Event (TLL) Marker up Marker up Marker down Tilt angle down Marker left Range up Marker left Marker switching Marker switching...
  • Page 79 Chapter 2 2 Function setting KDS-60 00BB 2.5.3 Sto ore in [CM] keys The presen nt settings a are stored i n the [CM] k key current tly lit green. There is no o special op peration nec cessary for storage.
  • Page 80 S-6000BB Chapte ter 2 Funct tion setting Function n keys ([F] keys) [F] k eys can be e assigned w with the fun nctions use d frequently y, to be ope erated with one touch opera ation. 2.6.1 1 Setting t to function n to [F] key The f...
  • Page 81 Chapter 2 Function setting KDS-6000BB Remote control set Select the [Remote control set] function at Menu2. Refer to Chapter 3 “3.2 Remote control” (page 3-9) Maintenance Refer to Installation Manual Chapter 3 “Maintenance” 2-46 0093160002-00...
  • Page 82 S-6000BB Chap pter 3 Oper ration keys Chapter r 3 Ope eration k keys 3.1 T To use key Operati ion unit of KDS-6000B 3.1.1 1 Present ation mode e key Selec ct one of the display y mode, [S Sonar], [So onar (Off-ce enter)], [Bo...
  • Page 83 Chapter 3 3 Operation n keys KDS-60 00BB 3.1.3 Sec ctor key Change th e scanning historical a angle (secto or angle) in the Sonar m mode. Change th e scanning sector ang le (vertical a angle) in th e Bottom-s can mode.
  • Page 84 S-6000BB Chap pter 3 Oper ration keys 3.1.5 5 TVG key offsets th e effects o of propaga tion loss o of sound a s it passes s through the water. Prop pagation los s of sound is the sum o of spreadin g and atten nuation loss...
  • Page 85 Chapter 3 3 Operation n keys KDS-60 00BB 3.1.6 Pow wer/Panel brightness s key Powe On/O Off. Powe On Press to pow er on. On start-up p, the intern nal memory y (ROM and d RAM) is a automatical ly checked , if the chec cking completes...
  • Page 86 S-6000BB Chap pter 3 Oper ration keys 3.1.8 8 Bearing center key this key to d define the c center of cu rrent scann ning sector i in Sonar m mode. bearing ang gle of the di splay is shi ifted with ev very 5°...
  • Page 87 Chapter 3 3 Operation n keys KDS-60 00BB 3.1.9 Tilt t key Use this ke ey to contro ol the tilt ang gle in the S Sonar mode Press 5゜ 0゜ hanges this ang gle. こ の角度(俯角)を を変更する レンジ 旋回中心 セクター...
  • Page 88 S-6000BB Chap pter 3 Oper ration keys Varia able tilt angl 3° st ep: -3° to -9 90° (every 3 3°) 5° st ep: -5° to -9 90° (every 5 5°) Refe er to page 2 -16 for step to d define the d direction of t the detectio...
  • Page 89 Chapter 3 3 Operation n keys KDS-60 00BB Turn rig ht: Increase e the range e (Ring ma arker), Move e to the up pper side (C Cross curso r), Move to o the depth direction (D Depth marke er), Move t o the right d direction (S...
  • Page 90 S-6000BB Chap pter 3 Oper ration keys 3.2 R Remote co ontrol (RCW W-14) (Optio onal) arget lock ke Turn on or o off the target t lock mode. ・ Hois st key ・ Up ploads/down nloads the Tran nsducer unit t key Adjust tilt an ngle.
  • Page 91 Chapter 3 3 Operation n keys KDS-60 00BB Hul unit U/D Target lock Tilt angle up Event (TLL) Marker up Tilt angle dow Marker left Marker switch hing Marker right 4. Turn (knob/l left) to selec ct the settin ng number f from [A1] to [D3] The re...
  • Page 92: Chapter 3 Operation Keys

    KDS-6000BB Chapter 3 Operation keys ・Set as the same way as other Remote key setting. ・The sheet of remote control key shows the initial setting of the remote control keys. ・The range operation of Remote control key; [Range up]: Move to shallow range.
  • Page 93 pter 4 App pendix S-6000BB Chapt ter 4 Append d ix External view and d dimensions Proc cessor unit t (DPU-610) eration uni it (DOU-620 Unit: mm (i nch) 0093 160002-00...
  • Page 94 KDS-6000 apter 4 App pendix TD positio on alam de vice (JB-36 In n stallation dimension Remote co ontroller (R RCW-14) (O Optional) Unit: mm ( (inch) 00931600 002-00...
  • Page 95 4 App pendix KDS-6000BB Hull unit (DHU- -630) 0093 160002-00...
  • Page 96: Chapter 4 Appendix

    KDS-6000BB Chapter 4 Appendix Disposal Dispose of this equipment in accordance with local regulations. 0093160002-00...
  • Page 97: Chapter 5 Index

    KDS-6000BB Chapter 5 Index Chapter 5 Index A scope ..............2-1 Echo sounder ............1-1 Absorption and attenuation ........xv Echo sounder mode ........1-15, 1-16 Attenuation ............xvii Enter ..............1-2 Ext synchronized ........2-2, 2-25 External navigator ........1-13, 1-15 Baud rate ............
  • Page 98: Power Voltage Alarm

    Chapter 5 Index KDS-6000BB Key Name ............1-1 Panel brightness ..........1-8 km: kilometer ............2-28 Power freq adjust ........2-1, 2-30 km/h ..............2-28 Power voltage ............1-5 kn: knot...............2-28 Power voltage alarm ..........1-5 knob/left............... 1-3 Power/Panel brightness ........1-1 knob/right .............
  • Page 99: Tvg Key

    KDS-6000BB Chapter 5 Index Sub-screen (transparent) ......2-2, 2-39 Sub-screen display ........2-1, 2-13 Sub-screen selection ........2-1, 2-12 Ultrasonic beams ..........xvii Surface layer ............xvi Ultrasonic wave ............ xv Sweep time ............1-11 VRM ..............1-2 Target lock .......... 1-2, 2-1, 2-23 VRM key ..............