Koden KDS-5000BB Operation Manual
Koden KDS-5000BB Operation Manual

Koden KDS-5000BB Operation Manual

Digital
Table of Contents

Advertisement

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KDS-5000BB and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Koden KDS-5000BB

  • Page 5 Koden Electronics Co., Ltd. The technical descriptions contained in this publication are subject to change without notice. Koden assumes no responsibility for any errors, incidentals or consequential damages caused by misinterpretation of the descriptions contained in this publication.
  • Page 6 • Koden is not liable for any damages caused by earthquake, lightning, wind and flood damage and fire for which Koden is not responsible, and actions by third parties, other accidents, customer’s unintended error/abuse and the use under other abnormal conditions.
  • Page 7 When the inside is to be checked, ensure to switch off the power and to discharge the residual voltage for safety. An engineer authorized by Koden shall carry out the inspection and maintenance works.
  • Page 8 In case of failure, please Warning contact Koden’s dealers or Koden. In case of smoking or firing, switch off the power in the boat and of this equipment. It may lead to firing, electric shock or damages.
  • Page 9: Table Of Contents

    CONTENTS SONAR OPERATION Chapter 1 Introduction………………..….….…………… Before Use……………….…………… 3 For Your Safety…………...…………. Components……………….…………. Chapter 2 Installation…………………………………….. Chapter 3 Basic Operation………………….…………… Chapter 4 Function Settings…………………………… Factory Settings…………..……………. 46 Menu………………………………….. Function Settings………...…………… 51 ……………..… 83 Chapter 5 Description of Knobs and Keys Knobs…………………….……………...
  • Page 10 We are confident you will enjoy using your unit for many years to come. This manual provides complete information on safely operating the KDS-5000BB. Please carefully read and follow the safety information so that the KDS-5000BB will perform to the utmost of its ability. Symbols...
  • Page 11: Before Use

    BEFORE USE SYMBOLS The following symbols are used in this manual.  Please read this manual carefully and take note of these symbols.  Indicates an imminently hazardous situation which, if not avoided, DANGER will result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, WARNING could result in death or serious injury.
  • Page 12: Turning The Power On/Off

    BEFORE USE TURNING the POWER ON/OFF POWER ON ON Press the POWER key on the Operation unit. “Please wait!” appears on the screen. The Transducer unit is automatically lowered if “TD AUTO DOWN – ON” previously set. In case “TD AUTO DOWN – OFF” is previously set, it is lowered only after pressing the Lower key ( ↓...
  • Page 13: For Your Safety

    Away as much as possible from areas of high temperatures or areas where the unit is likely to be exposed to direct sunlight. MOUNTING CONDITIONS Do not install the KDS-5000BB on unstable or uneven surfaces. WARNING Installing the unit tentatively may result in dropping, toppling over or injury.
  • Page 14: Power Supply

    FOR YOUR SAFETY POWER SUPPLY Use the proper voltage. Otherwise it will result in fire or electrical shock. WARNING Turn on/off the power by ON/OFF keys on the Operation unit. Turning on/off the power by the switchboard may damage the unit. CAUTION Turn off the power when starting the ship engine.
  • Page 15: Components

    Type DPU-510 31524D-1 36213D Q’TY Name of item Operation manual Audio system plug Fuse Tapping screw Type KDS-5000BB.OM.E MP-105LC-RoHS FGBO-A-125V-4A M6x20 Q’TY OPERATION UNIT (DOU-520) Name of item Operation unit Mounting bracket Tapping screw BOLT KG-B2 2 PCS Type...
  • Page 16 COMPONENTS HULL UNIT (DHU-530) Name of item Hull unit Shaft guides Gum packing Crank handle Damper for flange Type DHU-5301 ESR-1510 ESR-1512 OB-63 34924D Q’TY Name of item TD shaft Fixing collar Shift cap Bolt set ×8 ×8 ×8 ×8 Type ESR-1504 (1411mm) 32681D...
  • Page 17 COMPONENTS JUNCTION BOX (DJB-540) Name of item Junction box Fuse Tapping screw DJB-540 Type DJB-540 FGBO-A-125V-4A SUS-M5x20 FGBO-A-125V-8A Q’TY 3 each - 9 -...
  • Page 18: Chapter 2 Installation

    CHAPTER 2 INSTALLATION This Chapter explains the installation of KDS-5000BB. Installation Position of Hull Unit Installation Dimensions Processor unit (DPU-510) Dimensions Operation unit (DOU-520) Dimensions Junction box (DJB-540) Dimensions Hull unit (DHU-530) TD tank Assembling and Mounting of Hull unit (DHU-530)
  • Page 19: Installation

    INSTALLATION Fully discussion and agreement are required with the ship owner and dockyard in deciding the location for the Hull unit. Give careful considerations to the installations. INSTALLATION POSITION of HULL UNIT Select an area where noise, interference and bubbles are minimal. The point at 1/3 to 1/2 of the ship’s length from the bow or near the keel is the best.
  • Page 20: Dimensions Processor Unit (Dpu-510)

    INSTALLATION DIMENSIONS: PROCESSOR UNIT (DPU-510) DIMENSIONS: OPERATION UNIT (DOU-520) Unit: mm (inch) - 12 -...
  • Page 21: Dimensions Operation Unit (Dou-520)

    INSTALLATION DIMENSIONS: OPERATION UNIT (DOU-520) Unit: mm (inch) - 13 -...
  • Page 22: Dimensions Junction Box (Djb-540)

    INSTALLATION DIMENSIONS: JUNCTION BOX (DJB-540) Unit: mm (inch) - 14 -...
  • Page 23: Dimensions Hull Unit (Dhu-530)

    INSTALLATION DIMENSIONS: HULL UNIT (DHU-530) Unit: mm (inch) - 15 -...
  • Page 24: Td Tank

    INSTALLATION TD TANK 1. MAINTENANCE SPACE When installing the TD tank, pay full attention to the safety (strength, water-tightness, etc.). At the same time, secure a space for maintenance and inspections. - Since the Hull unit is not a waterproof structure, keep it away from water drops and splashes.
  • Page 25 INSTALLATION 2. TD TANK INSTALLATION CONDITIONS Satisfy the following installation conditions. - Installation point should be 1/3 to 1/2 of the ship’s overall length back from the bow. - If it cannot be installed on the keel, the center of the TD tank should be within 1 meter of the keel.
  • Page 26 INSTALLATION 3. TD TANK INSTALLATION EXAMPLES - Select a location of TD tank. Refer to page 11 -Make a hole of TD tank diameter in the bottom of ship. HULL KEEL TD TANK HOLE -Install the TD tank. Flange should be positioned in parallel with the ship’s draft in sailing.
  • Page 27 INSTALLATION -Make the surrounding of the TD tank projecting out from the bottom in a stream line shape and provice a fairing plate to suppress water resistance and generation of air bubbles to the minimum. FAIRING PLATE -Apply FRP sufficiently to all the necessary parts to prevent leakage of water.
  • Page 28: Assembling And Mounting Of Hull Unit (Dhu-530)

    INSTALLATION ASSEMBLING and MOUNTING of Hull unit (DHU-530) 1. TD SHAFT Calculate necessary length of TD shaft (Standard length of 1681mm) from the length of TD tank (Lt) and cut off the unnecessary portion. TD SHAFT LENGTH = TD TANK LENGTH (Lt) + 181mm 2.
  • Page 29 INSTALLATION 3. ASSEMBLING of the TD shaft and the Transducer unit 1) Screw TD shaft into the Transducer unit. Make sure not to damge the TD shaft or twist the Transducer unit Cable. Totally wipe dirts and grease from the threaded parts of the Transducer unit and TD shaft. Apply adhesive, waterproof sealer (Bathcork;...
  • Page 30 INSTALLATION 2) Mount Shaft Guides Instert the 3 shaft guides as shown in the drawing. Insert Fixing Collar and fix it with the Cap Bolts (2 pcs). FIXING COLLAR CAP BOLT M4X10 SHAFT GUIDES <To be continued> - 22 -...
  • Page 31 INSTALLATION 3) Mount the Transducer unit on the Hull unit -Apply Grease inside the nuts and the Flange. -Unscrew the nuts. Pass the TD shaft through the Flange assembly. Pass the Damper through and align the bow mark on the Transducer unit with the mark on the Flange assembly.
  • Page 32 INSTALLATION ) Mount the shaft cap at the end of TD shaft Insert the shaft cap into the TD shaft. Screw it with the cap bolts, M4x25 (4 pcs). Screw the cap bolts, M4x10 (4 pcs) to prevent slip-out of the shaft cap. Ensure the bolt position each.
  • Page 33 INSTALLATION ) Assemble Hull unit with TD tank Insert Gum Packing between Hull unit and TD tank. Use 8 Hex.Bolts (M16x65) to fit Hull unit in TD tank. Check the performance of hoisting/lowering of the Transducer unit several times while tentatively clamping with Hex.Bolts and fasten them after the performance is confirmed.
  • Page 34 INSTALLATION 4. HOW TO ADJUST HOISTING and LOWERING STROKE The stroke of hoisting/lowering of the Transducer unit can be adjusted from the minimum, 180mm to the maximum, 380mm by adjusting the switch shown in the drawing. Find the proper lowering position of the Transducer unit with this Switch. Moved up and down Raised Position 380mm...
  • Page 35: Mounting Junction Box (Djb-540)

    INSTALLATION MOUNTING of JUNCTION BOX (DJB-540) The mounting location should be well ventilated and dry. Avoid locations subject to watersplash or rain. Allow enough service clearance. The Cable Junction side should be at the bottom side or the left side. Cable Junction at the left Truss Tapping Screw Cable Junction at the bottom...
  • Page 36: Mounting Processor Unit/ Operation Unit

    INSTALLATION MOUNTING of PROCESSOR UNIT/ OPERATION UNIT PROCESSOR UNIT 1) Fasten the Processor Unit to the mounting location with 4 Truss Tapping Screws. Components Processor Unit Truss Tapping Screw Truss Tapping Screw OPERATION UNIT 1) Fasten the M. Bracket to the mounting location with 4 Truss Tapping Screws. 2) Fit the Operation unit to the M.
  • Page 37: Processor Unit (Rear Side)

    INSTALLATION PROCESSOR UNIT (REAR SIDE) Trigger Output Terminal (3P) outputs trigger signals Alarm Terminal (2P) synchronizing to an external USB Terminal for using USB relay contact for an external alarm echo sounder. VGA Output Terminal (OPTION) Speaker Terminal connects an external monitor connects an optional speaker.
  • Page 38: Wiring Junction Box (Djb-540)

    INSTALLATION WIRING JUNCTION BOX (DJB-540) Main Fuse Motor Fuse For Main Power Supply of Junction Box For Hoist Motor Use the specified fuse as follows, Use the specified fuse as follows, 24V→4A. 24V→8A. Power Supply Cable Hoist Motor Cable connects the Hoist Motor Cable from the connects the DC power supply Hull unit.
  • Page 39: Wiring Warnings

    INSTALLATION WIRING WARNINGS Connect the cables to the Hull unit, the Junction Box, the Processor unit or the Operation unit referring to the following instructions. WARNING - The DC Power Supply connected to the main unit each is as follows, DPU-510 Processor unit : 21.6 to 31.2 volts...
  • Page 40 INSTALLATION WIRING between DPU-510 and DHU-530 OPERATION UNIT COMMUNICATION CABLE 1 BATTERY VOLTAGE: FUSE: HOIST PROCESSOR UNIT SWITCH VGA OUTPUT TERMINAL FUSE POWER SUPPLY BATTERY VOLTAGE CABLE INTERFACE MAIN CABLE 15m (POWER) MOTOR HOIST MOTOR CABLE 5.3m LIMIT SWITCH CABLE 5.5m POWER SUPPLY TRANSDUCER UNIT CABLE...
  • Page 41 INSTALLATION WIRING JUNCTION BOX (DJB-540) connects the white line to 24V according to the voltage of the battery. 4 BINDING SCREWS BATTERY (M4X8) 4pcs HOIST MOTOR CABLE connects J2 on the board. BLACK LIMIT SWITCH CABLE connects 6P plug to J 7 on the board.
  • Page 42: Chapter 3 Basic Operation

    CHAPTER 3 BASIC OPERATION This Chapter explains the basic operation of KDS-5000BB. Operation Panel Basic Operation Display Description Sample Display of Sonar Mode Sonar Mode Sample Display of Bottom-Scan Mode Bottom-Scan Mode Sample Display of Sounder Mode Sounder Mode - 34 -...
  • Page 43: Basic Operation Operation Panel

    BASIC OPERATION OPERATION PANEL Sensor Lamp Power ON/OFF Keys Refer to page 87 Refer to page 87 Hoist Keys Mark key Refer to page 87 Refer to page 93 Lower Keys Refer to page 87 Cursor Shift Keys (▲/▼/ Cursor Selection Keys Refer to page 90 (Ring Marker/Cross Cursor) Refer to page 90...
  • Page 44: Display Description

    BASIC OPERATION DISPLAY DESCRIPTION The drawing below shows the typical sonar mode display. Various combination displays are available by selecting the Sub-Display menu and the change of the Mode Knobs. RANGE 160m BEARING S 0゜ W SECTOR 360゜ TILT -30゜ IR-1...
  • Page 45: Sample Display Of Sonar Mode

    BASIC OPERATION SAMPLE DISPLAY of SONAR MODE Select MODE KNOB ( ) to display SONAR MODE or MODE KNOB ( ) to display OFF-CENTER MODE. HORIZONTAL DISTANCE RANGE SLANT DISTANCE BEARING 86.0m R 160m DEPTH B 0゜ 99.3m SECTOR S 360゜ 49.7m...
  • Page 46: Sonar Mode

    BASIC OPERATION SONAR MODE Rotating the transducer in the Transducer unit protruded from the ship’s bottom, the ultra sound beams are sent out and detects the targets in accordance with the selected speed and the range (distance). The reflected sound appears on the PPI depending on the transducer’s sweep. Adjusting the Tilt and Bearing the sonar beam can be trained from the surface to the bottom.
  • Page 47 BASIC OPERATION The Tilt angle can be set in increments of 1° from 0° to 5° to 0° to -90°. All directions from extremely shallow waters to deep areas can be searched. Adjust the tilt angle considering the conditions such as ship’s speed and water depth. 5゜...
  • Page 48: Sample Display Of Bottom-Scan Mode

    BASIC OPERATION SAMPLE DISPLAY of BOTTOM-SCAN MODE Select MODE KNOB ( ) to display the BOTTOM-SCAN MODE. SHIP’S POSITION TILT ANGLE T-90゜ B27 0゜ 0 32 SCALE (RANGE) 64 CROSS CURSOR RANGE MARKER 96 100 SEA BOTTOM ECHO 128 SCALE (SECTOR) 160...
  • Page 49: Bottom-Scan Mode

    BASIC OPERATION BOTTOM-SCAN MODE Shaking the transducer in the Transducer unit protruded from the ship’s bottom right and left alternately, it sends out the ultra sound beams and displays the images of the middle layer and the sea-bottom contour. The transducer emits the ultra sound beams sweeping the transducer right and left.
  • Page 50: Sample Display Of Sounder Mode

    BASIC OPERATION SAMPLE DISPLAY of SOUNDER MODE Select MODE KNOB ( ) to display the SOUNDER MODE. TILT ANGLE WATER TEMPERATURE 24.7 °C TIME MARKER T-60 B 0 ゜ ゜ 0 32 SEA SURFACE SCALE 64 BEARING ECHO (RANGE) INDICATOR 96...
  • Page 51: Sounder Mode

    BASIC OPERATION SOUNDER MODE The transducer in the Transducer unit protruded from the ship’s bottom sends out the ultra sound beams and displays the images of the middle layer and the sea-bottom contour, which are just beneath the ship. Sounder Mode The transducer emits the ultra sound beams toward the bottom just beneath the ship and the...
  • Page 52: Chapter 4 Function Settings

    CHAPTER 4 FUNCTION SETTINGS This Chapter explains the function settings of KDS-5000BB. Select the appropriate setting for performing to the utmost of its ability before use. Factory Settings Menu Menu 1 Menu 2 Function Settings Gain Up Function Set TVG Curve...
  • Page 53 Others Audio Level Target Lock Trigger Signal Depth Unit Temp. Unit (Temperature Unit) Temp. Adjust (Temperature Adjustment) Speed Unit Auto Retract Train Correct Panel Brightness Power Supply Frequency TD Auto Down Ope. Mode Memory Color Sel. (Color Selection) Color Palette Color (Display Colors) Remote Control Set Frequency Setting...
  • Page 54: Factory Settings

    FACTORY SETTINGS FACTORY SETTINGS The factory settings are shown in the below box. Select the desired settings before use. FUNCTION SETTINGS FACTORY SETTINGS (shown in AA) Referring page FUNCTION SET MENU 2 OFF  +10dB  +20dB  +30dB  +40dB  +50dB GAIN UP PAGE 51-56 OFF ...
  • Page 55 FACTORY SETTINGS COLOR PALETTE MENU 2 A-1  A-2  B-1  B-2  C-1  C-2 COLOR SEL. PAGE 76-77 8  16 COLOR FREQUENCY SETTING PAGE 79 TX FREQUENCY 180.0kHz (±10kHz / 0.1kHz UNIT) RX FREQUENCY 180.0kHz (±10kHz / 0.1kHz UNIT) - 47 -...
  • Page 56: Menu

    MENU MENU 1 “ ” (RANGE SETTING MENU) Select the display range in 8 settings according to the depth desired. The following menu appears after selecting “ ” with the MODE KNOB. RANGE SET MENU SONAR/OFF-CENTER RANGE BOTTOM-SCAN/F.F. RANGE Use the Cursor Shift key to highlight the item to change.
  • Page 57 MENU MENU 2 “ ” (FUNCTION SETTING MENU) Customize the functions to suit individual needs before using the KDS-5000BB. The basic settings are as follows. FUNCTION SET GAIN UP TVG CURVE DYNAMIC RANGE PULSE WIDTH TX POWER RX GAIN RED.
  • Page 58 MENU COLOR PALETTE COLOR SEL. COLOR REMOTE CONTROL FREQUENCY SETTINGS TX FREQUENCY RX FREQUENCY SELF CHECK MAINTENANCE UPDATE BACK UP RECOVERY VERSION For further details see next pages. - 50 -...
  • Page 59: Function Settings

    FUNCTION SETTINGS Turn the MODE KNOB to “ ” to display the below menu. The item currently selected is highlighted. Use the Cursor Shift key to select the desired item. Press the O / + to open the menu for change. Cursor Selection key MENU 2 Use the Cursor Shift key...
  • Page 60: Gain Up

    FUNCTION SETTINGS 1. GAIN UP This function makes it possible to display a clearer picture of the full range and control the sensitivity at various depths. ) to select “GAIN UP”. Use the Cursor Shift key ( Use the Cursor Shift key ( ) to change the setting.
  • Page 61: Tvg Curve

    FUNCTION SETTINGS 2. TVG CURVE TVG (Time Variable Gain) offsets the effects of propagation loss of sound as it passes through the water. To counter this loss, the TVG curve is adjusted by correctly set. ) to select “TVG CURVE”. Use the Cursor Shift key ( Use the Cursor Shift key ( ) to change the setting.
  • Page 62: Dynamic Range

    FUNCTION SETTINGS 3. DYNAMIC RANGE This is the way to display the reactions with emphasis or with density discrimination. ) to select “DYNAMIC RANGE”. Use the Cursor Shift key ( Use the Cursor Shift key ( ) to change the setting. DYNAMIC RANGE Use the Cursor Shift key ( ) to change.
  • Page 63: Tx Power

    FUNCTION SETTINGS 5. TX POWER The output power of the ultra sound wave from the transmitter can be set. ) to select “TX POWER”. Use the Cursor Shift key ( Use the Cursor Shift key ( ) to change the setting. TX POWER Use the Cursor Shift key ( ) to change.
  • Page 64: Rx Bandwidth

    FUNCTION SETTINGS 7. RX BANDWIDTH RX bandwidth can be set. ) to select “RX BANDWIDTH”. Use the Cursor Shift key ( Use the Cursor Shift key ( ) to change the setting. RX BANDWIDTH STANDARD Use the Cursor Shift key ( ) to change.
  • Page 65 FUNCTION SETTINGS REJECTION [MODE KNOB – – REJECTION] REJECTION O / + to return to MENU 2. RETURN MARK Use the Cursor Shift key ( INTERFERENCE REJ. to select the desired item to change. Use the Cursor Shift key ( to change the settings.
  • Page 66: Sub-Display

    FUNCTION SETTINGS DISPLAY ITEM SELECTION DISP ITEM SEL Press the Cursor Selection key O / + to return to MENU 2. RETURN MARK SUB-DISPLAY Use the Cursor Shift key ( STEP (SONAR) to select the desired item to change. STEP (BOTTOM-SCAN) OFF-CENTER POS.
  • Page 67 FUNCTION SETTINGS 2) INFO (INFORMATION) This sub menu “INFO” can be displayed when one of the Mode Knobs, “ ”selected. RANGE 160m BEARING 0゜ SECTOR 360゜ TILT -30゜ IR-O N MARKER 86.0m 99.3m 49.7m CURSOR 十 45゜ 65.2m 75.3m 37.7m POWER 24.3 V WATER 27.4゜C...
  • Page 68 FUNCTION SETTINGS 3) HISTORICAL DISPLAY The vertical images can be displayed as sub menu when SONAR MODE or BOTTOM- SCAN MODE set. Note that the normal echo sounder images are displayed on the whole screen when SOUNDER MODE is selected. PORT SIDE MARK・STARBOARD SIDE MARK 0...
  • Page 69 FUNCTION SETTINGS 4) +PRESS (COMPRESSED IMAGE AND HISTORICAL DISPLAY) The vertical images and their compressed image can be displayed when SONAR MODE or BOTTOM-SCAN MODE set. The normal echo sounder images and compressed image are displayed on the screen when SOUNDER MODE is selected. SONAR MODE SOUNDER MODE BOTTOM-SCAN MODE...
  • Page 70 Displays the mark placed by a Cross Cursor in the Sonar Mode. TRACK Displays the track line. The past line is memorized every interval set via 34゜36.974N 18.6kt 137゜01.698E “TRACK MEM.INTERVAL”. 24.7゜C 8) EXT.SOUNDER (EXTERNAL SOUNDER) This function is only available when some Koden units connected. - 62 -...
  • Page 71: Step (Sonar)

    FUNCTION SETTINGS 2. STEP (SONAR) The Step angle for SONAR MODE can be selected. ) to select “STEP (SONAR)”. Use the Cursor Shift key ( Use the Cursor Shift key ( ) to change the setting. STEP (SONAR) 10° Use the Cursor Shift key ( ) to change.
  • Page 72: Off-Center Position

    FUNCTION SETTINGS 4. OFF-CENTER POS. (OFF-CENTER POSITION) The displayed position of own ship on the screen can be selected when OFF-CENTER MODE is active. ) to select “OFF-CENTER POS.”. Use the Cursor Shift key ( Use the Cursor Shift key ( ) to change the setting.
  • Page 73: Compass Display

    FUNCTION SETTINGS 6. COMPASS DISPLAY Compass can be displayed in the SONAR MODE when an External Navigator connected. ) to select “COMPASS DISP.”. Use the Cursor Shift key ( Use the Cursor Shift key ( ) to change the setting. COMPASS DISP.
  • Page 74: Track Sub Range

    FUNCTION SETTINGS 9. TRACK SUB RANGE The screen width for Track display in sub menu can be selected. Refer to page 62 ) to select “TRACK SUB RANGE”. Use the Cursor Shift key ( Use the Cursor Shift key ( ) to change the setting.
  • Page 75: Filter

    FUNCTION SETTINGS 12. FILTER The image on the sonar can be enhanced by this function. ) to select “FILTER”. Use the Cursor Shift key ( Use the Cursor Shift key ( ) to change the setting. FILTER Use the Cursor Shift key ( ) to change.
  • Page 76 FUNCTION SETTINGS OTHERS [MODE KNOB – – OTHERS] Press the Cursor Selection key OTHERS O / + to return to MENU 2. RETURN MARK AUDIO LEVEL Use the Cursor Shift key ( TARGET LOCK MODE0 to select the desired item to change. TRIGGER SIGNAL INTERNAL DEPTH UNIT...
  • Page 77 FUNCTION SETTINGS 2. TARGET LOCK The desired target lock function can be selected, which is activated by pressing the Target Lock key while SONAR MODE or BOTTOM-SCAN MODE (only in case of MODE0) operated. It can change the rotary direction, trackthe target or the position specified with a cursor automatically.
  • Page 78 EXTERNAL: activates the signal from an external unit. (when another echo sounder synchronized) NOTE! The sweeping speed might be slower depending on the depth whe the KDS-5000BB is synchronizing with an external echo sounder. Using the internal trigger signal of KDS-5000BB is recommended for synchronizing with an external echo sounder.
  • Page 79 FUNCTION SETTINGS 4. DEPTH UNIT The unit of depth measurement can be selected. ) to select “DEPTH UNIT”. Use the Cursor Shift key ( Use the Cursor Shift key ( ) to change the setting. DEPTH UNIT Use the Cursor Shift key ( ) to change.
  • Page 80 FUNCTION SETTINGS 7. SPEED UNIT The unit of the ship’s speed displayed on the screen can be selected when an external navigator connected. ) to select “SPEED UNIT”. Use the Cursor Shift key ( Use the Cursor Shift key ( ) to change the setting.
  • Page 81 FUNCTION SETTINGS 9. TRAIN CORRECT This changes the center direction of the detection range into the bow direction (0°). Select the SONAR MODE and set the desired position by using the Bearing keys Open “MENU 2” and use the Cursor Shift key to select “OTHERS-TRAIN CORRECT”.
  • Page 82 FUNCTION SETTINGS 11. POWER SUPPLY FREQUENCY The switching frequency of the power supply is changed. The switching currents can cause electrical noise problems. The noise produced by the SMPS itself can be suppressed changing the frequency. It is usually not required to change the frequency other than noise problem. ) to select “POWER FREQUENCY”.
  • Page 83 FUNCTION SETTINGS 13. OPERATION MODE MEMORY The memory of Operation Mode is restricted. Refer to page 94 It can avoid memorizing the operation accidentally by selecting OFF. ) to select “OPE. MODE MEMORY”. Use the Cursor Shift key ( Use the Cursor Shift key ( ) to change the setting.
  • Page 84 FUNCTION SETTINGS COLOR PALETTE [MODE KNOB – MENU 2 – COLOR PALETTE] COLOR PALETTE Press the Cursor Selection key COLOR O / + to return to MENU 2. RETURN MARK B.G. Use the Cursor Shift key ( COLOR SEL. to select the desired item to change. COLOR Use the Cursor Shift key ( to change the settings.
  • Page 85 FUNCTION SETTINGS HOW TO SET COLOR PALLETTE Color palette can provide 2 color patterns (C-1 & C-2) freely. The initial color pattern of C-1 is the same with A-1 and C-2 are is the same with A-2. ) to select “C-1” or “C-2”, which activates the “INITIAL Use the Cursor Shift key ( SETTINGS”...
  • Page 86 FUNCTION SETTINGS REMOTE CONTROL SET (OPTION) Previously set the key each on the remote controller before use. [MODE KNOB – – REMOTE CONTROL SET] Refer to page 100 for the settings in details. - 78 -...
  • Page 87 Use the Cursor Shift key ( to change the settings. 1. TX FREQUENCY Adjust the transmitting frequency of the KDS-5000BB and the receiving frequency changes in conjunction with the transmitting frequency. It can be changed from the basic frequency to ±10kHz every 0.1kHz unit.
  • Page 88 FUNCTION SETTINGS SELF CHECK The following messages appear on the display. This function checks the battery voltage, the internal voltage, the hoist up and down or the conditions of the stepping motor in the Transducer unit. Use the Cursor Shift key ( ) to select SELF CHECK “RETURN MARK”...
  • Page 89 ELAPSED TIME It indicates the total time that elapses while the KDS-5000BB operating and can be reset. ) to select “ELAPSED TIME”. Use the Cursor Shift key ( The following menu appears on the bottom of the screen after pressing the Cursor Selection key (O / +).
  • Page 90 FUNCTION SETTINGS [HOW TO UPDATE VERSION] Insert the USB stick contains the upgraded files. ) to select “NEXT”. Use the Cursor Shift key ( Pressing the Cursor Selection key O / + updates the program. After rebooting the unit, it is operated with the updated version 2.
  • Page 91: Description Of Knobs And Keys

    CHAPTER 5 DESCRIPTIONS of KNOBS and KEYS This Chapter explains how to use the knobs and keys. Mode Knob Knobs Range Knob Sector Knob Gain Knob Far Gain Knob Keys Power ON/OFF Key Hoist/Lower Key Sensor Lamp Bearing Key Tilt Key Cursor key Target Lock Key Mark Key...
  • Page 92: Knobs

    KNOBS MODE KNOB The display mode is selected. The Sub-Display menu displayed in the right split screen can be set via “ ”. Refer to page 58 The own ship’s position in the Off-Center Mode can be set via “ ”.
  • Page 93: Sector Knob

    KNOBS SECTROR KNOB The horizontal training angle can be changed when SONAR MODE selected. The vertical training angle can be changed when BOTTOM-SCAN MODE selected. [SONAR MODE] [BOTTOM-SCAN MODE] Displays the selected sector angle CURSOR MARKER RANG E BEAR I NG SECTOR T I LT ANG LE Changes this angle...
  • Page 94: Gain Knob

    KNOBS GAIN KNOB Rotating this knob clockwise can adjust or increase the sensitivity of the sonar display. The gain value can be set via “ – ”. Refer to page 52 MENU 2 GAIN UP FAR GAIN KNOB Rotating this knob clockwise increases sensitivity of the sonar for the last half of the displayed range and adjusts the TVG curve.
  • Page 95: Keys

    ↑ : HOIST KEY / ↓ : LOWER KEY The Hoist and Lower keys raises and lowers the Transducer unit while operating the KDS-5000BB. Pressing the Hoist key raises the Transducer unit and the mark on the lower left screen changes into the up arrow ( .
  • Page 96: Bearing Key

    KEYS BEARING KEY [SONAR MODE] The center direction of the detection range can be shifted as follows. 5° step shift Displays values of Sector angle Shifts the center Shifts the center counterclockwise clockwise RANG E SEC TO R T I LT ANG LE MARKER This key changes CURSOR...
  • Page 97: Tilt Key

    KEYS TILT KEY [SONAR MODE] The tilt angle can be changed. 5゜ RANGE BEARING 0゜ Changes this angle. SECTOR TILT Displays MARKER Shifts upward. Tilt angle CURSOR TILT Shifts downward. Displays the Tilt angle. -90゜ Variable Tilt angle: in increments of 1° from -5° ( 0°) to -90° [BOTTOM-SCAN MODE] The scanning center can be shifted.
  • Page 98: Cursor Key

    KEYS [SOUNDER MODE] The direction of emitting the sound wave and the bearing of the detection can be shifted together with “BEARING KEY”. Indicator Indicator Tilt angle Bearing angle Use the Tilt key to set this angle. Displays of the bearing angle RANGE BEARING Displays of the tilt angle...
  • Page 99 KEYS [when the power turned on] No cursors appear on the screen when the power turned on. Press the Cursor selection key (O / +) to activate the function. Press the Cursor shift keys ( ) to display the Marker. Press the Cursor selection key again to activate this function.
  • Page 100: Target Lock Key

    KEYS [when the Cross cursor selected] (Marker displayed in yellow or no display) In case of SOUNDER MODE this function is inactive. Use the Cursor shift keys to place the cursor where desired. The data of the “Cross Cursor” is displayed in the submenu. SONAR MODE BOTTOM-SCAN MODE RANGE...
  • Page 101: Mark Key

    KEYS MARK KEY ( ) The Mark key functions to mark desired locations on the screen, and 5 marks can be inscribed at the Cross cursor locations desired. Move the Cross cursor to the desired locations and press the Mark key. The Mark appears at the Cross cursor location and moves with ship’s movement.
  • Page 102: Operation Mode Key

    KEYS OPERATION MODE KEY 3 different types of customized operation settings can be registered previously. Press one of the Operation mode keys to operate the units with the desired settings soon after pressing it. Open MENU 2 display and press one of the Operation mode keys. The following “OPERATION MODE”...
  • Page 103: Chapter 6 Option

    CHAPTER 6 OPTION This chaper provides you the explanation related to the optional input/output terminals and the remote controller. Option Option List Input/Output Terminals Input/Output Terminals (Processor unit) Remote Controller - 95 -...
  • Page 104: Option List

    OPTION OPTION LIST For Processor unit P. No. Description ESR-1809-SET Remote Controller Set With 4m cable and cable for connecting remote controller with OP-287 connecter. OP-360 XGA Connect Cable Assy Terminal for XGA Output (to connect an external monitor) OP-190 Trigger Output Cable 36981D To connect Trigger Output to the Sounders of other companies...
  • Page 105 OPTION P. No. Description ESR-1510 Shaft guides ESR-1511 Shaft guides with adjuster G-100 Grease Bath cork - 97 -...
  • Page 106: Input/Output Terminals

    The following optional terminals are required to connect a remote controller and an External monitor. This is to indicate the settings for the interface setups. Note that the connection cables between the KDS-5000BB and the external units to be connected are not supplied as standard. P. No.
  • Page 107: Input/Output Terminals (Processor Unit)

    OPTION INPUT/OUTPUT TERMINALS (PROCESSOR UNIT) Remove all cables connected to the Processor unit before mounting any terminals. 1) Remove 4 Binding Screws holding the Lid of the Processor unit and remove the Lid (Drawing A position). DANGER Remote ControllerTerminal VGA Terminal Do not open the Case Cover thoughtlessly.
  • Page 108: Remote Controller

    OPTION REMOTE CONTROLLER Connect the terminal of the Remote Controller to the specified port Bearing Key changes the center direction right Hoist Key or left. raises the Transducer unit. Tilt Key Lower Key adjusts the Tilt Angle. lowers the Transducer unit. Mark Key Target Lock Key enters the Mark.
  • Page 109: Additions

    ADDITIONS DISPOSAL WARNING The KDS-5000BB contains the lithium battery of high-density energy. Careless disposal of the lithium battery causes electric shorts, impact, heat, electrical shock, explosion, injury, fire and so on. DISPOSAL OF KDS-5000BB Dispose of the KDS-5000BB in accordance with local regulations.
  • Page 110: Specifications

    ADDITIONS SPECIFICATIONS Item Content Model KDS-5000BB Processor unit DPU-510 Operation unit DOU-520 Hull unit DHU-530 Output power (RMS) 1.5kW Output frequency 180kHz Tilt angle +5° to -90° (1°step) Beam angle 10° 180 to 380 mm (Recommended value 180 mm) TD stroke...

Table of Contents