IBM System x3530 M4 Product Manual page 33

Hide thumbs Also See for System x3530 M4:
Table of Contents

Advertisement

Supported environment:
Air temperature
Server on: 5 °C - 40 °C (41.0 °F - 104 °F); altitude: 0 - 915 m (3,000 ft).
Server on: 5 °C - 32 °C (41.0 °F - 89.6 °F); altitude: 915 - 2,134 m (7,000 ft).
Server on: 5 °C - 28 °C (41.0 °F - 82.4 °F); altitude: 2,134 - 3,050 m (10,000 ft).
Server off: 5 °C - 45 °C (41.0 °F - 113 °F).
Shipment: -40 °C - 60 °C (-40 °F - 140 °F).
Humidity
Server on: 8% - 85%, maximum dew point 24 °C, maximum rate of change 5 °C/hr.
Server off: 8% - 80%, maximum dew point 27 °C.
Shipment: 5% - 100%.
Design to ASHRAE Class A3, ambient of 35 °C - 40 °C, with relaxed support
Supports a cloud like workload with no acceptable performance degradation (Turbo-Off).
Under no circumstance can any combination of worst case workload and configuration result in
system shutdown or design exposure at 40 °C.
Electrical
Models with 675 W hot-swap power supplies:
100 - 127 (nominal) V AC; 50 Hz or 60 Hz; 7.8 A
200 - 240 (nominal) V AC; 50 Hz or 60 Hz; 3.8 A
Input kilovolt-amperes (kVA) (approximately):
Minimum configuration: 0.14 kVA
Maximum configuration: 0.77 kVA
Models with 460 W hot-swap power supplies:
100 - 127 (nominal) V AC; 50 Hz or 60 Hz; 5.6 A
200 - 240 (nominal) V AC; 50 Hz or 60 Hz; 2.8 A
Input kilovolt-amperes (kVA) (approximately):
Minimum configuration: 0.12 kVA
Maximum configuration: 0.53 kVA
Models with 460 W fixed power supplies:
100 - 127 (nominal) V AC; 50 Hz or 60 Hz; 6.0 A
200 - 240 (nominal) V AC; 50 Hz or 60 Hz; 3.0 A
Input kilovolt-amperes (kVA) (approximately):
Minimum configuration: 0.13 kVA
Maximum configuration: 0.57 kVA
BTU output
Minimum configuration: 406 Btu/hr (119 watts)
Maximum configuration: 2627 Btu/hr (770 watts)
Noise level
6.5 bels (operating)
6.3 bels (idle)