COMBUSTION AIR INTAKE OPTION: The RF000142 coupling can be secured directly to the furnace intake coupling if conden-
sation is a concern. If the RF000142 is used on the combustion air inlet, it must be installed with the arrow pointing up. It
should be noted, the combustion air will actually be moving in a direction opposite of the arrow on the RF000142 coupling. It
must have a field supplied, trapped drain tube free-draining to proper condensate disposal location. A loop in the drain tube
can serve as a trap. The unused RF000142 drain fitting should be capped. (See Figure 9B)
N
-D
V
I
ON
IRECT
ENT
NSTALLATIONS
A minimum of one 90° elbow should be installed on the combustion
air intake "coupling" to guard against inadvertent blockage.
A
V
/F
L
LTERNATE
ENT
LUE
OCATION
The alternate vent/flue location is the large hole directly in line
with the induced draft blower outlet. To use the alternate vent/flue
location refer to the following steps and the "Alternate Vent/Flue
Location" figure. To use an alternate vent location on a
counterflow / horizontal model, a special kit is required.
NOTE: In the horizontal left installation position, a means of
condensate collection must be provided to keep vent pipe con-
densate from entering the draft inducer housing. If the vent
drain elbow is eliminated from the installation, an RF000142
kit must be used.
1. Remove the four screws from the vent pipe flange on top
the furnace.
2. Remove the internal elbow and vent pipe
3. Cut 2 1/2" from the flange .
4. Remove plastic plug in line with the inducer outlet
5. Install cut end of the flanged section and connect to inducer
with rubber coupling supplied with furnace.
6. Install screws removed in step 1 securing flange to cabinet.
T
HE RUBBER ELBOW IS NOT DESIGNED TO SUPPORT A LOAD
RUBBER ELBOW IS MOUNTED EXTERNALLY TO THE FURNACE CABINET
EXTREME CARE MUST BE TAKEN TO ADEQUATELY SUPPORT FIELD
/
,
SUPPLIED VENT
FLUE PIPING
CAUSING BODILY INJURY OR DEATH DUE TO EXPOSURE TO FLUE GASES
INCLUDING CARBON MONOXIDE
A
C
A
LTERNATE
OMBUSTION
IR
(Upflow / Horizontal models only)
When using the alternate venting location, either in a horizon-
tal left side down installation or a vertical installation using down – venting, an alternate combustion air opening can be
used. A locating dimple is located on the right side of the furnace cabinet. The locating dimple is 1 7/8" measured from the
front edge of the cabinet in line with the knock out. To use the alternate combustion air location:
1. Remove screws and combustion air flange from cabinet.
2. Insert cabinet plug in unused combustion air hole.
3. Drill a pilot hole at the cabinet dimple (size dictated by knockout tool used).
4. Use a knockout tool to create a 3" diameter hole
5. Install combustion air flange and secure with screws removed in step one.
WARNING
. W
AS DAMAGE CAN RESULT IN LEAKS
P
ROVISION
E
DGES OF SHEET METAL HOLES MAY BE SHARP
PRECAUTION WHEN REMOVING HOLE PLUGS
Insert flange. Cut 2 ½" long.
HEN THE
,
-
,
15
WARNING
. U
SE GLOVES AS A
.
RF000142
Figure 10
Figure 11
Vent/Flue Pipe Cuts