Electrical Adjustment
Group/Item Item Name
6 Temp B Warning (Normal)
7 Temp C Warning (Normal)
8 Temp B-A Warning (Normal)
9 Temp C-A Warning (Normal)
10 Temp A Warning (Eco)
11 Temp B Warning (Eco)
12 Temp C Warning (Eco)
13 Temp B-A Warning (Eco)
14 Temp C-A Warning (Eco)
15 Temp A Warning Offset (Temp)
16 Temp B Warning Offset (Temp)
17 Temp C Warning Offset (Temp)
18 Temp B-A Warning Offset (Temp)
19 Temp C-A Warning Offset (Temp)
20 Temp A Warning Offset (Time)
21 Temp B Warning Offset (Time)
22 Temp C Warning Offset (Time)
23 Temp B-A Warning Offset (Time)
24 Temp C-A Warning Offset (Time)
254
Fan Control Range Setting (Temp/Frequency)
0 High Fan Control Min Temp
1 High Fan Control Max Temp
2 High Fan1 Min
3 High Fan1 Max
4 High Fan2 Min
5 High Fan2 Max
6 High Fan3 Min
7 High Fan3 Max
8 High Fan4 Min
9 High Fan4 Max
10 Normal Fan Control Min Temp
11 Normal Fan Control Max Temp
12 Normal Fan1 Min
13 Normal Fan1 Max
14 Normal Fan2 Min
15 Normal Fan2 Max
16 Normal Fan3 Min
17 Normal Fan3 Max
18 Normal Fan4 Min
19 Normal Fan4 Max
20 Eco Fan Control Min Temp
21 Eco Fan Control Max Temp
22 Eco Fan1 Min
23 Eco Fan1 Max
24 Eco Fan2 Min
25 Eco Fan2 Max
26 Eco Fan3 Min
27 Eco Fan3 Max
28 Eco Fan4 Min
29 Eco Fan4 Max
255
Fan Start/Cooling Setting
0 Fan1 Initial Volt
1 Fan2 Initial Volt
2 Fan3 Initial Volt
3 Fan4 Initial Pulse
4
5
6
7
8 Cooling Time
9
10 Temp Error Cooling Time
11 OnStaart Cooling Start Threshold
12 After shutdown cooling
256
Fan Lamp Voltage Setting
Function
Temp B (Lamp) to judge the Failure at Normal Mode
Temp C (Panel) to judge the Failure at Normal Mode
Temp B-A (Clog) to judge the Failure at Normal Mode
Temp C-A (Clog) to judge the Failure at Normal Mode
Temp A (Room) to judge the Failure at Eco Mode
Temp B (Lamp) to judge the Failure at Eco Mode
Temp C (Panel) to judge the Failure at Eco Mode
Temp B-A (Clog) to judge the Failure at Eco Mode
Temp C-A (Clog) to judge the Failure at Eco Mode
Offset of Temp of Temp Error (Temp)
Offset Error Temp under the following condition.
- In the standby
- Startup period of the Lamp-on
- Switching period of the Lamp Mode
Offset of Temp of Temp Error (min)
Offset Error Time under the following condition.
- In the standby
- Startup period of the Lamp-on
- Switching period of the Lamp Mode
Temp Sensor Control Start/End Temp. at High
Fan Operation Frequency (Min/Max) Setting at High
(rpm)
Temp Sensor Control Start/End Temp. at Normal
Fan Operation Frequency (Min/Max) Setting at Normal
(rpm)
Temp Sensor Control Start/End Temp. at Eco
Fan Operation Frequency (Min/Max) Setting at Eco (rpm)
Fan Start Voltage (x0.1)
Fan Start Output
Cooling Time Setting (x30)
1: 30, 3: 90, 15: 45 sec.
Cooling Setting at Temp Error (x30)
1: 30, 3: 90, 15: 45 sec.
0: No, 1: Yes
Initial
67
67
67
67
52
52
52
52
100
100
100
100
100
100
100
100
47
47
47
47
67
67
67
67
51
51
51
51
100
100
100
100
100
100
100
100
10
11
13
11
13
30
15
15
15
15
Norm
Ceil
Up
Down
30
30
30
30
39
39
39
39
2775
2775
2775
2775
2975
2975
2975
2975
1800
1800
1800
1800
2555
2555
2555
2555
4700
4700
5900
5900
4800
4800
6100
6100
3120
3120
3120
3120
5865
5865
5865
5865
30
30
30
30
39
39
39
39
2495
2495
2495
2495
2795
2795
2795
2795
1625
1625
1625
1625
2245
2245
2245
2245
3650
3650
4850
4850
3725
3725
5000
5000
2605
2605
2605
2605
5275
5275
5275
5275
30
30
30
30
39
39
39
39
2210
2210
2210
2210
2610
2610
2610
2610
1450
1450
1450
1450
1935
1935
1935
1935
2600
2600
3800
3800
2650
2650
3900
3900
2090
2090
2090
2090
4685
4685
4685
4685
55
65
35
700
3
3
38
1
-70-
Range
Note
30-100
30-100
0-100
20°
0-100
160°
L1
30-100
30-100
Normal
Ceiling
30-100
L2
0-100
200°
340°
0-100
(-160°)
(-20°)
0-100
0-100
Slant
Off
L1
Ceiling
0-100
Off
Normal
Up
Down
0-100
On
Ceiling
Up
Down
0-100
Definition of Slant
0-40
Off
-20° ~ 20°
L1
20° ~ 160°
0-40
L2
-20° ~ -160°
0-40
0-40
0-40
20-100
20-100
0000-9990
0000-9990
0000-9990
0000-9990
0000-9990
0000-9990
0000-9990
0000-9990
20°
160°
L1
20-100
20-100
Normal
Ceiling
0000-9990
0000-9990
L2
200°
340°
0000-9990
(-160°)
(-20°)
0000-9990
0000-9990
Slant
0000-9990
Off
L1
Ceiling
Off
Normal
Up
Down
0000-9990
On
Ceiling
Up
Down
0000-9990
Definition of Slant
20-100
Off
-20° ~ 20°
20-100
L1
20° ~ 160°
L2
-20° ~ -160°
0000-9990
0000-9990
0000-9990
0000-9990
0000-9990
0000-9990
0000-9990
0000-9990
0-255
0-255
0-255
0-4095
1-15
1-15
0-100
0-1
L2
L2