BASIC SERIAL COMMAND
FUNCTIONAL SPECIFICATIONS
PLC-ET30L
SANYO Electric Co., Ltd
Personal Mobile Group
DI Company
Projector Business Division

Advertisement

Table of Contents
loading

Summary of Contents for Sanyo PLC-ET30L - 4200 Lumens

  • Page 1 BASIC SERIAL COMMAND FUNCTIONAL SPECIFICATIONS PLC-ET30L SANYO Electric Co., Ltd Personal Mobile Group DI Company Projector Business Division...
  • Page 2: Table Of Contents

    PLC_ET30L Basic Serial Command Functional Specifications Contents 1. Overview ..........................4 2. Serial Interface Specification ...................4 2.1. Transfer Specification ....................4 2.2. Connection ........................4 3. Notes for Communication ....................5 4. Functional Execution Command Table ................6 5. Status Read Command Table ...................7 6. Functional Execution Command ..................8 Format ........................8 When the command pipelining is needed ............8 Transfer Example ....................8...
  • Page 3 PLC_ET30L Basic Serial Command Functional Specifications 6.32 POWER MANAGEMENT CANCEL Command ........... 14 6.33 POWER MANAGEMENT SHUTDOWN Command ..........14 6.34 D.ZOOM + Command ................... 14 6.35 D.ZOOM - Command .................... 15 6.36 INPUT 3 AUTO Command..................15 6.37 INPUT 3 VIDEO Command .................. 15 6.38 INPUT 3 S-VIDEO Command ................
  • Page 4: Overview

    PLC_ET30L Basic Serial Command Functional Specifications 1. Overview 0û These specifications define projector control commands for PLC-ET30L. 0û The projector control commands are used to control a projector through RS-232C from a computer. 2. Serial Interface Specification 2.1. Transfer Specification Item S p e c i f i c a t i o n Synchronous system...
  • Page 5: Notes For Communication

    PLC_ET30L Basic Serial Command Functional Specifications 3. Notes for Communication 0û The projector command is defined as one command per line that starts with “C” and ends with carriage return (0x0D). 0û When carriage return (0x0D) is received, decoding starts. 0û...
  • Page 6: Functional Execution Command Table

    PLC_ET30L Basic Serial Command Functional Specifications 4. Functional Execution Command Table Command Command Item Item POWER ON BRIGHTNESS + POWER OFF (QUICK POWER OFF) BRIGHTNESS - POWER OFF INPUT 2 VIDEO INPUT 2 Y,Pb/Cb,Pr/Cr INPUT 1 INPUT 2 RGB INPUT 2 INPUT 3 IMAGE NETWORK...
  • Page 7: Status Read Command Table

    PLC_ET30L Basic Serial Command Functional Specifications Command Item Command Item FREEZE ON FREEZE OFF ZOOM - ZOOM + AUTO PC ADJ FOCUS - PRESENTATION TIMER FOCUS + KEYSTONE ! ‘ KEYSTONE ! “ INPUT 1 ANALOG RGB INPUT 1 SCART INPUT 1 DVI (PC DIGITAL) INPUT 1 DVI (AV HDCP) Lens Shift Up...
  • Page 8: Functional Execution Command

    PLC_ET30L Basic Serial Command Functional Specifications 6. Functional Execution Command 6.1 Format 0û PC issues a command in the following format: “C” Command [CR] Command: two characters (See Functional Execution Command Table) 0û Projector decodes the received data and returns the result when getting ready to receive the next command.
  • Page 9: Operation Requirements

    PLC_ET30L Basic Serial Command Functional Specifications 6.4 Operation Requirements In the following status of projector, Available Functional Execution Commands are limited. Projector Status Available Functional Execution Commands Standby Mode C00: POWER ON C00: POWER ON ! ’ Countdown is terminated C01: POWER OFF C02: POWER OFF ! ’...
  • Page 10: Power On Command

    PLC_ET30L Basic Serial Command Functional Specifications 6.5 POWER ON Command Command “C00” [CR] Power ON Detail When already Power is ON, no operation is started. When sending this command during Countdown in process, Countdown is terminated. Acceptable [ACK] [CR] Response Unacceptable “?”...
  • Page 11: Input 3 Command

    PLC_ET30L Basic Serial Command Functional Specifications 6.10 INPUT 3 Command Command “C07” [CR] Select Input 3. This command works differently from the command by “Input 3” Detail key of the remote control. When Input 3 has been selected, this command does not execute the source switching;...
  • Page 12: Video Mute On Command

    PLC_ET30L Basic Serial Command Functional Specifications 6.16 VIDEO MUTE ON Command Command “C0D” [CR] Video Mute ON Detail This command works the same way as “NO SHOW” button of the remote control for No Show ON, but does not work for No Show OFF. Acceptable [ACK] [CR] Response...
  • Page 13: Display Clear Command

    PLC_ET30L Basic Serial Command Functional Specifications 6.22 DISPLAY CLEAR Command Command “C1E” [CR] Detail Clear On-screen Display under all conditions Acceptable [ACK] [CR] Response Unacceptable “?” [CR] 6.23 BRIGHTNESS + Command Command “C20” [CR] Detail Increment Brightness by 1 according to user control. Acceptable [ACK] [CR] Response...
  • Page 14: On Start Set Command

    PLC_ET30L Basic Serial Command Functional Specifications 6.29 ON START SET Command Command “C28” [CR] Enable Power ON Start Detail This status is stored in EEPROM and retained regardless of Power OFF/ON operation. Acceptable [ACK] [CR] Response Unacceptable “?” [CR] 6.30 ON START CANCEL Command Command “C29”...
  • Page 15: D.zoom - Command

    PLC_ET30L Basic Serial Command Functional Specifications 6.35 D.ZOOM - Command Command “C31” [CR] Enter Digital Zoom mode and reduce image size Detail This command works the same as “D.ZOOM ▼” button of the remote control. Acceptable [ACK] [CR] Response Unacceptable “?”...
  • Page 16: Pointer Up Command

    PLC_ET30L Basic Serial Command Functional Specifications 6.41 POINTER UP Command Command “C3C” [CR] Move up the Pointer of On-Screen Display Menu Detail This command works the same way as “▲” button of the projector. Acceptable [ACK] [CR] Response Unacceptable “?” [CR] 6.42 POINTER DOWN Command Command “C3D”...
  • Page 17: Zoom - Command

    PLC_ET30L Basic Serial Command Functional Specifications 6.47 ZOOM - Command Command “C46” [CR] Reduce image size Detail This command works the same way as “ZOOM ▼” button of the remote control. Acceptable [ACK] [CR] Response Unacceptable “?” [CR] 6.48 FOCUS + Command Command “C4B”...
  • Page 18: Input 1 Dvi (Av Hdcp) Command

    PLC_ET30L Basic Serial Command Functional Specifications 6.53 INPUT 1 DVI (AV HDCP) Command Command “C53” [CR] Detail Select DVI (AV HDCP) input of Input 1 Acceptable [ACK] [CR] Response Unacceptable “?” [CR] 6.54 LENS SHIFT UP Command Command “C5D” [CR] Detail Move projection area upward.
  • Page 19: Presentation Timer Command

    PLC_ET30L Basic Serial Command Functional Specifications 6.59 PRESENTATION TIMER Command Command “C8A” [CR] Start Timer for presentation This command works the same way as “P-TIMER” button of the Detail remote control. Acceptable [ACK] [CR] Response Unacceptable “?” [CR] 6.60 KEYSTONE ↑ Command Command “C8E”...
  • Page 20: Status Read Command

    PLC_ET30L Basic Serial Command Functional Specifications Status Read Command 7.1 Format 0û PC issues a command in the following format. “CR” Command [CR] Command: one character (See Status Read Command Table) 0û When projector receives an appropriate command, it returns the required data in string. Required Data [CR] Required Data: string (See Status Read Command Table) 0û...
  • Page 21 PLC_ET30L Basic Serial Command Functional Specifications 0 Details for Response0 0û “00” [CR] Status: Power ON Normal image is on-screen. “80” [CR] 0û Status: Standby When the status is Standby, Status Read Commands are always accepted, but any Functional Execution Commands are not accepted except for POWER ON command. 0û...
  • Page 22 PLC_ET30L Basic Serial Command Functional Specifications 0û “88” [CR] Status: Standby after Cooling Down due to Abnormal Temperature When the status becomes Standby after the temperature goes down by Cooling Down operation invoked due to Abnormal Temperature, the projector returns “88” [CR]. This indicates Abnormal Temperature caused turning to Standby status.
  • Page 23: Input Mode Read Command

    PLC_ET30L Basic Serial Command Functional Specifications 7.4 Input Mode Read Command Command “CR1” [CR] Detail Get currently selected Input No. Acceptable “%1” [CR] ”1” = Input 1 is selected. “2” = Input 2 is selected. Response “3” = Input 3 is selected. “4”...
  • Page 24: Lamp Mode Read Command

    PLC_ET30L Basic Serial Command Functional Specifications 7.8 Lamp Mode Read Command Command “CR7” [CR] Get lamp mode. Detail In the projector with single lamp, get ON/OFF status of the lamp Acceptable “%1” [CR] “00” [CR] = Lamp is ON. Response “01”...