Control Board Operation
START BUTTON
The "START" Button turns on the pellet stove.
If the exhaust does not reach operating tempera-
ture within 30 minutes, the stove will automati-
cally shut down. The pellet stove can be restarted
by pushing the "START" Button again.
RESTART
AUGER ON (green LED) - The auger restarts and
returns to delivering fuel to the UltraGrate™.
STOP BUTTON
Note: The "START" Button has to be activated to
give power to the AUGER ON/OFF button.
The "STOP" button turns the pellet stove OFF.
When the LED is green, the auger is ON.
SHUT DOWN (LED off) - Auger turns OFF and
fuel delivery stops. The blowers will continue to
operate until the stove has cooled sufficiently.
Stove enters shut down mode.
HEAT OUTPUT BUTTON
When not using a wall thermostat, the "HEAT
OUTPUT" button provides the ability to burn
at five separate settings from low (#1) to high
(#5). The "HEAT OUTPUT" button regulates the
fuel feed setting and the combustion air supply
simultaneously.
Each time the "HEAT OUTPUT" button is pressed
the heat output will advance to a higher setting.
When at the highest setting (#5), if the button
is pressed again it will go back to the lowest
setting. Settings can be changed at any time
but will only take affect after the start-up cycle
is complete.
CONVECTION (ROOM AIR) BLOWER
BUTTON
The "BLOWER" button operates the convection
blower. This will change the flow of hot air into
the room. Five settings are available from low
(#1) to high (#5). When the "BLOWER" button
is pressed, the green indicator light will scroll
from low to high. When at the highest setting
(#5), if the button is pressed again it will go
back to the lowest setting.
When the "HEAT OUTPUT" button is on position
#5, the lowest blower setting is #3. When the
heat output button is on position #4, the lowest
blower setting #. This is a safety precaution
to protect against overheating. Blower settings
can be changed at any time, but will only take
affect after the start-up cycle is complete.
Note: The control board has an internal memory
which recalls the last setting prior to loss of
power.
18
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
Note: If the fuel feed trim or combustion air trim needs to be adjusted, contact your dealer or
qualified technician to calibrate internal software. The trim controls should only be adjusted for
the proper flame if all other options did not achieve proper adjustment. It is recommended that the
damper be used to fine-tune your stove to your particular fuel and installation configuration (see
Damper Adjustment on Page 9 and Damper Adjustment Guidelines on Page 20).
Combustion
Blower Trim
COMBUSTION
Heat Output
AIR
O
Button
(-)
(+)
Convection
HEAT
START
(room air)
OUTPUT
Blower
Button
BLOWER
Convection
PELLET
FEED
(room air)
(-)
Blower LEDs
- Green
FEEDING
(5 places)
STOP
m 5 - High
m 4 - Med. High
m 3 - Medium
HEARTH PRODUCTS
m  - Med. Low
m 1 - Low
Figure 22 -
Control Board
Fuel Delivery Rate
The "HEAT OUTPUT" button manages the fuel delivery rate by controlling the amount of time the
auger motor will run as follows:
Heat Output
Auger Motor OFF/ON
Setting
Time (seconds)
(#5) High =
1.6 / 0.6
(#4) Med.High =
1.8 / 0.6
(#3) Med.=
1.9 / 0.6
(#) Med.Low =
2.9 / 0.6
(#1) Low =
3.8 / 0.6
Table 5 - Model Montage™ 32FS
* Feed rates are approximations only. Actual feed rate will vary depending on size, quality and length of
fuel used and variations in line voltage.
w Estimated heat input based on fuel value of 8400 BTU per lb. of fuel.
Never empty pellets from the Burn-Pot into the hopper. Pellets that
may appear to be cool may retain enough heat to ignite other pellets
resulting in smoke or fire damage.
DO NOT OVERFIRE THIS STOVE. This may cause serious damage to
your stove and void your warranty. It also may create a fire hazard in
your home. IF ANY EXTERNAL PART OF THE UNIT BEGINS TO GLOW,
YOU ARE OVERFIRING. Immediately press the "STOP" button on the
control board.
4 Position
Start
Connector
Button
Heat Output
Main
LEDs - Red
Wire
(5 places)
Harness
Connector
Auger LED
O
Green = On
(+)
P/N
Label
Location
Stop
Button
Figure 23 -
* Lb.'s Per Hour
w Approximate BTU Per
Fuel Delivery
Hour Fuel Delivery
3.8 Lb.'s /hr.
3.0 Lb.'s /hr.
2.5 Lb.'s /hr.
2.0 Lb.'s /hr.
1.5 Lb.'s hr.
Note: Maximum hopper capacity is 55 lb.'s
WARNINGS
Convection
Blower
Speed Trim
To Thermostat
Terminal
Fuse
Back Side of Control Board
Burn Time
(hours)
32,000 BTU/hr
15
25,000 BTU/hr
18
21,000 BTU/hr
22
17,000 BTU/hr
31
13,000 BTU/hr
37

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents