INSTALLATION AND OPERATION MANUAL
Free-Standing
EPA Certified
Wood-Burning Stoves
Save These Instructions
For Future Reference
P/N 775215M, Rev. F, 09/2011
A French manual is available upon request. Order P/N 775215CF.
Ce manuel d'installation est disponible en francais, simplement en faire la demande. Numéro de la
pièce 775215CF.
Report # 050-S-03b-2
This appliance must be properly installed and operated in order to prevent the pos-
sibility of a house fire. Please read this entire installation and operation manual
before installing and using your wood stove. Failure to follow these instructions
could result in property damage, bodily injury or even death. Contact your
local building or fire officials to obtain a permit and information on any
installation requirements and inspection requirements in your area.
Portland
US
Hot! Do not touch! The glass and surfaces of this appliance will
be hot during operation and will retain heat for a while after
shutting off the appliance. Severe burns may result.
Carefully supervise children in the same room as appliance.
Performer ST210
and SWS210
Models Performer™ SS210,
ST210 and SWS210
WARNINGS
Performer SS210
Wood Stoves

Advertisement

Table of Contents
loading

Summary of Contents for Lennox Hearth Products PERFORMER SS210

  • Page 1 EPA Certified Wood-Burning Stoves Save These Instructions For Future Reference P/N 775215M, Rev. F, 09/2011 Performer ST210 Performer SS210 and SWS210 Wood Stoves Models Performer™ SS210, ST210 and SWS210 A French manual is available upon request. Order P/N 775215CF. Ce manuel d’installation est disponible en francais, simplement en faire la demande. Numéro de la pièce 775215CF.
  • Page 2: Table Of Contents

    Stove Installation ................. 12 Pedestal Installation ..............13 Thank you for selecting a Lennox Hearth Products wood stove as the answer to your home supplemental heating needs. Post Installation Checks ............... 14 Brick Installation ..............14-15...
  • Page 3: Important Safety Information

    ing season to check for soot and creosote accumulations. IMPORTANT SAFETY AND WARNIING Any accumulations over 1/8” thick should be removed by INFORMATION a professional chimney sweep. Do not attempt to burn out heavy creosote accumulations with a hot fire. If large ac- READ THIS MANUAL IN ITS ENTIRETY AND UNDER- cumulations are occurring, review your burning procedures.
  • Page 4: Testing Information

    performance problems as well as be a safety hazard. A draft test should TESTING INFORMATION read greater than .04’ W.C. (inches water column) and less than .08” W.C. As per NFPA-211 standard (see paragraph below), the installer must take into account all variables within the installation and install the This manual describes the installation and operation of these non-catalytic appliance in such a manner that satisfies the draft requirements of the wood heaters.
  • Page 5: Negative Pressure Warning

    (cat. no. H8159), available from all you need to clean to be safe. Be aware that the hotter the fire the Lennox Hearth Products dealers. less creosote is deposited, and weekly cleaning may be necessary...
  • Page 6: Clearances To Combustibles

    Chimney and Connector CLEARANCES TO COMBUSTIBLES Minimum 6" diameter, minimum 24 MSG black steel connector pipe with WARNING: BE ABSOLUTELY SURE THE DISTANCE BETWEEN THE UL103HT listed factory-built chimney suitable for use with solid fuels HEATER AND THE SURFACE OF ANY COMBUSTIBLE CONSTRUC- or masonry chimney.
  • Page 7: Installation Clearances

    INSTALLATION CLEARANCES - REFER TO FIGURES 2, 3 ANd 4 PIPE INSTALLATION B (1) D (1) E† F (1,4) Single Wall Residential USA-16” 13-3/4” USA-24” 14-1/2” 8” 9” CAN-483mm 349mm CAN-635mm 368mm 200mm 229mm Residential USA-10” 7-3/4” USA-24” 14-1/2” 8” 9” Single w/ Pipe CAN-330mm 197mm CAN-635mm...
  • Page 8: Typical Installation Figures

    Single Wall Pipe STAINLESS STEEL LINER Using 6” Diameter Single Wall Connector Pipe Using 6” Diameter Rigid Stainless Steel Liner INSTALL VENTING SYSTEM PER VENT MANUFACTURERS INSTALL VENTING SYSTEM PER VENT MANUFACTURERS INSTRUCTIONS! INSTRUCTIONS! Chimney Chimney Termination Termination Rain Cap Shown with Tubinox™ Stainless Steel Liner components (see Page 29 for ordering information)
  • Page 9: Chimney Installation

    CHIMNEY INSTALLATION Double Wall Pipe • Install chimney as per manufacturer’s instructions. Some brands of Using 6” Diameter Type L-Vent Connector Pipe pipe may require removal of the spacer ring in the flue collar. Mobile (Manufactured) Home Installation Shown • All horizontal runs of pipe should be as short as possible and are INSTALL VENTING SYSTEM PER VENT MANUFACTURERS required by NFPA No.
  • Page 10: Chimney - Wall Pass-Through Requirements

    Chimney Connector Systems and Clearances from Combustible System A Walls for Residential Heating Appliances (NFPA 211) Refer to Minimum chimney clearance to brick Figure 8 and combustibles 2 in. (51mm) System A. Minimum 3.5 in. (90 mm) thick brick masonry wall Minimum clearance 12 in.
  • Page 11: Leg And Heatshield Installation

    Open all cartons, if any and remove the contents upon receipt and check BACK for any damaged or missing parts. If there is hidden damage, notify your freight company or Lennox Hearth Products dealer immediately. Heat Shield Mounting Holes CAUTION: Wear gloves during installation in case of sharp edges on the stove.
  • Page 12: Stove Installation

    14. All horizontal runs of pipe should be as short as possible and are STOVE INSTALLATION required by NFPA No. 211 to have an upward pitch or rise in the same direction the smoke travels of no less than 1/4” to the linear foot. The connector pipe must meet minimum clearances in any direction If not previously installed, install floor protection and move the to walls or other combustible materials.
  • Page 13: Pedestal Installation

    If required, install the Outside Air Kit (P/N 71112) as per the fol- PEDESTAL INSTALLATION lowing instructions. To locate the hole in the hearth for outside air mark and cut a 4” (102 mm) hole in the hearth. The hole’s (For ash drawer pedestal see instructions included with pedestal) center should be 3”...
  • Page 14: Post Installation Checks

    POST INSTALLATION CHECKS BRICK INSTALLATION CAUTION: Wear gloves during brick installation in case of Check that all chimney pipe joints are securely fastened. sharp edges inside the stove. Check that the heater is securely fastened to the floor (if ap- Note: Installation of the baffle boards and baffle blankets are easier when plicable).
  • Page 15 Also included with the unit are two 15” x 10” x 1” thick baffle blankets. Install each blanket above the baffle board to each side of the second- ary support with the 15” side of the blanket from front to rear of the unit. Make sure that the baffle blankets are to the full rear of the unit. CAUTION: Make sure the baffle blankets are down flat on the baffle boards, pulled together in the center so that no gaps exists between them and do not protrude beyond baffle boards.
  • Page 16: Operating Hints

    OPERATING HINTS STARTING AND MAINTAINING A FIRE Be sure to clean plated accessories with a household type 1. Burn only dry, well-seasoned wood for maximum heat output. In some cleaner and a very soft cloth to remove any fingerprints and states it is illegal to burn wet wood or anything other than clean, dry wood products.
  • Page 17: Blower Operation (Optional Kit)

    BLOWER OPERATION Blower Operation The blower can be operated manually or automatically (blower will turn on when the stove is hot and turn off when the stove is cool). The rocker switch on the control panel allows you to select between manual operation or automatic operation as follows (see Figure 19): MANUAL OPERATION: Turn rocker switch to the “MANU- AL”...
  • Page 18: Operating Techniques And Hints

    What this can All Lennox Hearth Products stoves are EPA tested for emissions at low mean to you is longer, cleaner burns, less wood use and more heat.
  • Page 19: Maintenance

    DOOR HINGES: If door hinges need lubricating, use an anti-seize com- to cleaning glass. A commercial glass cleaner pound (never use oil) available from your Lennox Hearth Products dealer. designed for stoves is recommended. Do not use DOOR LATCH: If your door latch fails to latch tightly and the gasket is abrasive cleaners.
  • Page 20: Troubleshooting

    TROUBLESHOOTING Problem Solution POOR DRAFT: Extend chimney in length or have the chimney realigned to the proper size flue. Oversized chimneys normally have poor drafts. Remember, the stoves’ draft depend solely on the natural draft of the chimney (See Draft Requirements on Page 4).
  • Page 21: Do's And Don'ts

    Check the chimney and baffle monthly to make sure they are clean. Burn seasoned, dry wood only! (RAIN = WET WOOD) Open the door frequently during Burn-In Period to keep gasket from adhering to the curing paint. Enjoy the warm feeling of your new Lennox Hearth Products appliance.
  • Page 22 H5669 Single Black Olympic Leg H5622 Single Gold Olympic Leg Contact an Lennox Hearth Products dealer to obtain any of these parts. Never use substitute materials. Use of non-approved parts H5621 Single Nickel Olympic Leg can result in poor performance and safety hazards.
  • Page 23 REPLACEMENT PARTS - MODEL SS210 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
  • Page 24 REPLACEMENT PARTS - MODEL ST210 AND SWS210 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
  • Page 25 REPLACEMENT PARTS - MODELS SS210, ST210 AND SWS210 Door Parts Blower Parts NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
  • Page 26 REPLACEMENT PARTS - MODELS SS210, ST210 AND SWS210 Leg and Leg Parts NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
  • Page 27 REPLACEMENT PARTS - MODELS SS210, ST210 AND SWS210 Ash Drawer Pedestal and Pedestal NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
  • Page 28: Accessories

    ACCESSORIES - MODELS SS210 ACCESSORIES - MODELS ST210 AND SWS210 Product Reference Information Product Reference Information Cat. No. Description Ship. Ship. Cat. No. Description Ship. Ship. Weight Volume Weight Volume H7886 ST210A-B, Stove / Step Top / Arch 424 lb. 20.74 cu.
  • Page 29 ACCESSORIES - MODELS SS210, ST210 AND SWS210 Secure Black™ Single Wall Stove Pipe 6” SW Pipe and Accessories Cat. No. Model Description Pc. / Container Security Chimneys™ Pipe 6SWL6 6SWL6 LENGTH 6” X 6” 6SWL12 6SWL12 LENGTH 6” X 12” Tubinox Components 6SWL24 6SWL24...
  • Page 30: Accessories

    ACCESSORIES - MODELS SS210, ST210 AND SWS210 Cat. No. Model Description Pc. / Container Supports (continued) TEE SUPPORT Secure Temp® Factory-Built Chimney 6” Secure Temp ASHT and Secure Temp G-ASHT 6SMA 6SMA GALVALUME ADJUSTABLE TEE SUPPORT (2” TO 6”) Cat. No. Model Description Pc.
  • Page 31: Safety / Listing Labels

    SAFETY / LISTING LABEL - ENGLISH 2011 2012 2013...
  • Page 32: Safety / Listing Labels

    SAFETY / LISTING LABEL - FRENCH NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
  • Page 33 NOTES...
  • Page 34: Replacement Parts Lists

    The Date On Which Your Appliance Was Installed __________________________ Your Dealer's Name _________________________________________________ Lennox Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products.

This manual is also suitable for:

Performer st210Performer sws210 performer ss210

Table of Contents