  • Page 1 Mise à jour : 10/03/03 INSTRUCTION MANUAL FOR SPOT WELDING MACHINES GYSPOT P230 GYSPOT P400 GYSPOT 25D GYSPOT 32D...
  • Page 2 GYS can’t be responsible for the damages occurred to persons or things, which derive from the use of the machine in following circumstances: - Modification or neutralization of safety elements - Non respect of the recommendations written in the manual instruction.
  • Page 3: Electromagnetic Compatibility

    SMOKES AND GAZ Welding operations can cause the emission of toxic smokes and harmful metallic dusts. Use the device in a sheltered place equipped with smoke aspirators. The operator must wear an anti smoke mask. The welding material must be degreased and cleaned in order to limit the toxic gas during the welding process.
  • Page 4 - Directive Low Voltage 73/23 CEE of 19th February 1973 (decree n°95-1081 of 3rd October 1995) - Directive electromagnetic compatibility 89/336 CEE of 3rd May 1989 - Directive machines Under pressure 97/23 CEE of 29th November 1999 ( except GYSPOT P230 et P400)
  • Page 5 Compressed air : GYSPOT P230 et P400) Connect a compressed air pipe to the purifier behind the product. The service pressure can’t be over 10 bars. The product can’t be used on an air network with a pressure under 3 bars.
  • Page 6 GYSPOT 25D et 32D : Foreside Indicator of Button of power Indicator of Button of time Button of time adjustment. pneumatic loading. adjustment. power. adjustment. Button of mode selection . Mode D : Welding process on mild steel plates (1 pulsation).
  • Page 7 Blow off regularly the filter of un humidity on the back side of the product. Please adjust with a middle pressure of 6 bars. VIII/ COOLING AND THERMAL PROTECTION (except GYSPOT P230 et P400) The cables are cooled with compressed air. The cooling process can be permanent or controlled with an intern thermostat of the product ( selection with a button on the back side) A second thermal protection can forbid the use of the product in case of superheat.
  • Page 8: Operation

    IX/ RECOMMENDED ADJUSTMENTS FOR BODY CAR WORKSHOP (only indicative and to modulate depending on the type and the thickness of the sheets) GYSPOT P230 et P400 : TOOL OPERATION MODE POWER TIMER Welding of pins 4 to 10 Welding of nails and rivets...