Hanger Kit Installation
1. Position the hanger at the generator's balance point as shown
below.
2. Fit the end tabs of the hanger through the bracket slots, and bolt the
brackets to the hanger and tighten securely.
TORQUE: 17–22 lbf·ft (24–29 N·m, 2.4–3.0 kgf·m)
8×16 mm FLANGE BOLT (4)
HANGER
HANGER
11 in (280 mm)
ASSEMBLY
HANGER BRACKET (2)
GENERATOR
SIDE
83