PROGRAMMING THE DISPENSER (cont.)
1. ON/OFF/NIGHT switch:
ON: Enables all dispenser functions.
OFF: Disables all dispenser functions.
NIGHT: Disables dispense switches. Tank refill and heating still functions.
2. NORMAL/PROGRAM/RINSE switch:
NORMAL: Allows all dispenser functions. Must be in this position for dispensing.
PROGRAM: Allows access to program menus using touch pad and LCD screen.
RINSE: Disables hopper motors. Pressing dispense button on front door will
dispense dilution water and power whipper motor for ten seconds.
PROGRAMMING LOCKOUT SWITCH (on memory board mounted
on rear of component mounting bracket)
This switch can be set to prevent access to the programming
mode of the dispenser. Once all the correct settings are pro-
grammed, the operator can set the switch to the "ON" position to
prohibit anyone from changing the settings.
PROGRAMMING CUP SIZES - Portion Control Models
The cup size can be programmed in portion control models by "EXAMPLE" or "TIME". Programming by EX-
AMPLE is manually pressing desired dispense button, then releasing when the desired cup size is attained. The
time required to fill the cup will be stored in the controller memory when moving to the next menu. Program-
ming by TIME is setting the actual dispense time in seconds for each cup size desired.
Place the "NORMAL/PROGRAM/RINSE" switch in the "PROGRAM" position. Press button A (page 10) be-
low the BUNN logo on front of the door until the "SET CUP SIZE" menu is reached. (Refer to menu J, page 14)
Press button D (page 10) to select programming by "EXAMPLE". Place proper cup under dispense tip for station
you desire to set. Press desired dispense button, then release when the cup is 3/4 full. If cup is not full enough,
the dispense button can be pressed again to add additional beverage to the cup. If cup has reached desired level,
press button B under "SAVE" to record the dispense time. If cup is overfilled, press button D under "REPEAT".
Empty cup and repeat the process.
If setting cup sizes by "TIME" is desired, press button B under "TIME" in the "SET CUP SIZE" menu. "HEAD
1 SM TIME" will be displayed, along with current time setting. Pressing either button D below (-) or button B
below (+) will subtract or add time in .1 second increments. Each one second of time equals approximately 1.25
ounces of beverage at factory settings. When desired time is set, press button A to continue to next cup size.
When the desired cup sizes have been programmed, press button C to exit program menus, or press button
A to move to the next menu. If button C was selected to exit the program mode, return the "NORMAL/PRO-
GRAM/RINSE" switch to the "NORMAL" position to return to nomal operation.