8-2. Installation Diagram of Indoor and Outdoor Units

Before installing the
wireless remote control
• With the remote control cover
open, load the batteries supplied
correctly, observing their
polarity.
2
Wireless remote control
Cover
3
Batteries
5
18 Class
Sasa-Zeolite plus filter
6
Plasma air purifier
8
Pan head
wood screw
2
Wireless remote control
Extension drain hose
(Not available,
provided by installer)
Hook
1
4
Remote control holder
Vinyl tape
Apply after carrying
out a drainage test.
24 Class
− 34−
FILE NO. SVM-06005
For the rear left and left piping
Installation
plate
Insert the cushion between
the indoor unit and wall, and
tilt the indoor unit for better
operation.
Do not allow the drain hose to
get slack.
Shield pipe
Make sure to run the drain
hose sloped downward.
The auxiliary piping can be
connected to the left, rear left,
rear, right or bottom.
Right
Rear
Bottom
Saddle
Insulate the refrigerant pipes
Extension
separately with insulation, not
drain hose
together.
(Not available,
provided by
installer)
6 mm thick heat resisting
polyethylene foam
Wall
Cut the piping
hole sloped
slightly.
Left
Rear left