Ras-24Nkd-E5 / Ras-24Na-E, Ras-24Nkdx5 / Ras-24N2Ax - Toshiba RAS-18NKHD-E5 Service Manual

Split wall type
Table of Contents

Advertisement

5-2. RAS-24NKD-E5 / RAS-24NA-E, RAS-24NKDX5 / RAS-24N2AX

Cooling
0.39 m
(Connecting pipe)
∅15.88
P
O.D.:15.88 mm
Packed valve
(∅15.88)
Gas container connection (Reinstall etc.)
Compressor
PH400X3CS-4KT1
Cooling
50 Hz
Standard
Cooling
High temperature
Low temperature
Note : Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor.)
Indoor unit
Evaporator
Cross flow fan
Condenser
Propeller fan
Outdoor unit
Standard
Surface temp. of heat
pressure P
exchanger interchanging
(MPaG)
pipe T (°C)
0.43
0.56
0.32
– 16 –
FILE NO. SVM-06005
T
Packed valve
(∅6.35)
Capillary tube
∅ 2.4x700 s
Dryer
Refrigerant
R22 1.68 kg
Mark (
) means check points of Gas Leak
Fan speed
(indoor)
8.5
High
12.5
High
2.0
Low
0.49 m
(Connecting pipe)
∅6.35
O.D.:6.35 mm
Ambient temp.
conditions DB/WB
(°C)
Indoor
Outdoor
27/19
35/24
32/23
43/26
21/15
21/15

Hide quick links: