4.
FUNCTIONS OF CONTROLS AND INDICATORS
4.1 KEYPAD
Normal Operation Mode:
Keys 1 through 0: Used to enter the PIN
code.
# Key: Sounds an annunciator in the
Control Unit and also activates a 12
VDC output signal for use with an
external device.
*Key: Not used
Green LED indicator: Illuminates when
the door is released; flashes when
any key is pressed.
Programming Mode:
Keys 1 through 0: Used to enter
programming codes.
# Key: Used to terminate the
programming mode.
* Key: Used as a delimiter for
programming codes and parameters.
Green LED indicator:
Programming mode: Flashes
continuously
Valid programming entry: Single
flash
Invalid programming entry: Three
flashes
4.2 CONTROL UNIT
PENALTY Indicator LED: Illuminates
when the invalid PIN penalty feature is
activated.
AC POWER Indicator LED: Indicates
that the system is AC powered.
BATTERY Indicator LED: Indicates that
the system is battery powered.
OUTPUT VOLTAGE switch (24V or
12V): Selects the voltage that will
operate the locking device(s) attached
to the system.
OUTPUT MODE:
DIRECT position: Provides up to 2A of
continuous holding current.
LIMIT HOLDING CURRENT position:
Holding current is limited to
approximately 300 mA after the locking
device is initially energized. This setting
permits holding an electric lock or
strikes open without damaging its
solenoid. Note: Current limiting operates
only when the OUTPUT VOLTAGE
SOURCE switch is set to 24V.
LOW BAT Indicator LED: Indicates that
the battery is low.
BEEPER: See Table 6-1, Programming
Sequences
F1 and F2: 24VAC power, 2A Slo Blo
F3: Batteries, 2A Slo Blo
F4: Lock current, 2A Slo Blo
7