Shift Tray (D385)
2.8.2 INSTALLATION PROCEDURE
Unplug the copier power cord before starting the following procedure.
1.
Remove all tapes.
2.
Remove the plate [A].with nippers.
3.
Install the large paper guide [B] and two small paper guides [C], as shown.
4.
Install the stepped screw [A].
5.
Install the shift tray unit [B], as shown.
SM
2-36
D017/D018/D019/D020/D084/D085