Swift caravan Owner's Handbook Manual page 122

Table of Contents

Advertisement

WATER
(continued)
Problem
Possible Cause
Cold water pipe kinked preventing flow
Water flows from hot tap
Blockage in cold pipe line
but has reduced flow from
Cold tap not connected
cold
Cold tap failed or blocked
If a water filter is fitted, the cartridge is exhausted
Reduced flow from both
Battery condition low causing pump to run slowly
hot and cold taps
If new taps have been fitted they may be restricting flow
Pump needs servicing
Partially blocked pump filter or in-line filter, if fitted
Pump outlet pipe kinked restricting flow
Water leak
Reduced flow from
Y' connector(s) fitted incorrectly
either tap
Pipe kinking restricting flow
Bore size difference in taps
Warm water flows out of
Hot water back-feeding into cold line, usually if mixer
tap or single outlet hot and cold taps being used
cold tap
If pump motor runs
Battery voltage may be too low (below 10.5 volts)
steadily and will not stop
Remedy
Check and re-route if necessary
Disconnect pipes after 1st Y connector and check up to tap
Refer to installation instructions
Disconnect and inspect
Replace cartridge
Check battery state of charge, refer to electrical supply note
Disconnect and check that they have at least 1/4" (6.3mm) bore
Refer to pump servicing instructions
Dismantle and clean if necessary
Check and re-route if necessary
Check all water connections
Refer to installation instructions
Check and re-route if necessary
Use taps of equal bore size
Fit non-return valve in cold supply, near tap
Check that there is water in the container
Adjust switch and/or re-charge battery
Check all connections in pipework
Fault Finding
119

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents