. regularly. It is the responsibility of the client that these Nordpeis AS is not responsible for wrongly assembled stoves. regulations are complied with in the country/region where the fireplace is installed. Nordpeis AS is not The illustrations indicate the approximate centre height of the responsible for incorrect installation.
Uno 4 Releasing the stove from the pallet: Draught system Air vent control with Uno 1: Remove the screws holding the back cover start up air setting on the pedestal.Remove the back cover to acess det Combustion system Secondary combustion screws holding the stove to the pallet.
Uno 1/2: Do not have adjustable legs stove. Uno 4 Uno 1: The CE mark should be placed on the Open the door under the combustion chamber FIG 3. back of the pedestal. Remove the fitting covering the leg adjustment and adjust the legs with a 17 mm wrench.
Ignition air vent control takes some experience, but after a little while a natural As an integrated part of the air vent control, Uno has a rhythm for the fire will be found. ignition air vent control. By pushing the air vent control rod all the way back (max opening), the ignition air vent IMPORTANT! Always remember to open the air control will be activated.
Too many logs put on hot ember, may see the enclosed warranty card or visit our website result in combustion air starvation, and the gases will www.nordpeis.com be released unburnt. For this reason it is important to increase the air supply just after adding logs.
Page 7
oak and birch has the highest density. Attention! We do not recommend using fuel briquettes/ compact wood in our products. Use of such fuel may cause the product to overheat and exceed the temperatures determined safe. Burning briquettes/ compact wood is done so at your own risk and only small amounts (max 1/3 of normal load) should be used for each load.
Some advice in case of combustion problems Error Explanation Solution The chimney is blocked Contact a chimney sweeper / dealer for more information or clean The flue is sooty or there is accumulated soot on the the flue, smoke baffle and burn chamber. No draught smoke baffle The smoke baffle is wrongly positioned...
Page 9
FIG 1 >300 >500 >50 >250 >785 >795 >655 * m/isolert røykrør * w/insulated smokpipe * mit isoliertem Rauchrohr Se conformer aux règles nationales concernant les distances d’installation par rapports aux conduits de fumées...