Nordpeis Orion User Manual

Nordpeis Orion User Manual

Hide thumbs Also See for Orion:

Advertisement

Quick Links

Brukerveiledning
NO
User manual
GB
Instrukcja obsługi
PL
Produkt no:
SN-00000-000
Last updated:
25.10.2017
Test Report no: SP P0 09503-1, SINTEF 846042.07A, RRF 40 09 1922
2
8
13
Orion

Advertisement

Table of Contents
loading

Summary of Contents for Nordpeis Orion

  • Page 1 Orion Brukerveiledning User manual Instrukcja obsługi Produkt no: SN-00000-000 Last updated: 25.10.2017 Test Report no: SP P0 09503-1, SINTEF 846042.07A, RRF 40 09 1922...
  • Page 2: Important Safety Precautions

    All safety distances are minimum distances. Installation of the insert must comply with the rules and regulations of the country where installed. Nordpeis AS is not responsible for wrongly 6. Maintenance assembled inserts. The illustration indicates the approximate center height 7.
  • Page 3: Technical Information

    CO) and are thus better for the environment. Clean burning stoves require a small amount of wood in Top outlet FIG 3A: FIG 3B: FIG 3C: Product Orion Material: Cast iron Weight Stove 72 kg Rear outlet FIG 4:...
  • Page 4: Maintenance

    varnish on the stove will release some smoke or plates when the ashes are smell. Both the smoke and smell will disappear and not to damage them. Thermotte® Plates The wear time will depend on the individual use of strain and crack the plates, due to the tension created between the side plates.
  • Page 5: Warranty

    Open the ignition vent have established. used as it will burn better. The stoves from Nordpeis by use of the stove. 8. Advice on Lighting a Fire lighters and split small wood logs that are dry.
  • Page 6 Some advice in case of combustion problems Error Explanation Solution No draught must be installed in the room. more vents must be installed. the room. The stove release smoke when lighting the combustion not in use. results in no or very low draught. The stove releases smoke inside when...
  • Page 7 Orion = mm...
  • Page 8 FIG 1...
  • Page 9 Sidemontering / Lateral outlet...
  • Page 10 Toppmontering / Top outlet Bakmontering / Rear outlet FIG 4...
  • Page 12 Nordpeis AS Gjellebekkstubben 11 3420 Lierskogen, Norway Orion EN 13240:2001/A2:2007 Heating of living accomodation / Kamin zum Heizen mit festen Brennstoffen Year of Approval / Zulassungsjahr 2009 Fire safety: Feuersicherheit : Reaction to fire: Brandverhalten: A1 WT Distance to combustible:...
  • Page 13 Permanent pilot flame power requirement Pilot flame power requirement (if applicable) Contact details Name and address of the supplier: Nordpeis AS, Gjellebekkstubben 11, N-3420 LIERSKOGEN, Norway...
  • Page 14 Nordpeis AS. Nordpeis Orion ENERGIA · ЕНЕРГИЯ · ΕΝΕΡΓΕΙΑ · ENERGIJA · ENERGY · ENERGIE 2015/1186...
  • Page 15 www.nordpeis.no...

Table of Contents