Nordpeis Bergen Installation And User Manual

Nordpeis Bergen Installation And User Manual

Hide thumbs Also See for Bergen:

Advertisement

NO
Monterings- og bruksanvisning
GB
Installation- and user manual
SE
Installations- och bruksanvisning
FI
Kättöohje
Product no:
SA-BERG0-000
RRF no:
40 10 2244
Last updated:
01.01.2013
Bergen
2
9
15
21

Advertisement

Table of Contents
loading

Summary of Contents for Nordpeis Bergen

  • Page 1 Bergen Monterings- og bruksanvisning Installation- and user manual Installations- och bruksanvisning Kättöohje Product no: SA-BERG0-000 RRF no: 40 10 2244 Last updated: 01.01.2013...
  • Page 2: Chimney Draft

    2. Technical information regularly. It is the responsibility of the client that these regulations are complied with in the country/region 3. Distance to combustible material where the fireplace is installed. Nordpeis AS is not 4. Assembly responsible for incorrect installation. Operating control...
  • Page 3: Distance To Combustible Material

    All safety distances are minimum distances. Installation of the stove must comply with the current rules and regulations of the country where the product is installed. Nordpeis AS is not 4. Assembly responsible for wrongly assembled stoves.
  • Page 4: Lighting The Fire For The First Time

    For the flue connection to the chimney, follow the IMPORTANT! Always remember to open the air recommendations from the chimney manufacturer. vent control (preferably also the door) before new wood logs are inserted into a hot burn chamber. Fresh air supply Let the flames get a good grip on the wood before FIG 8: The possibility to connect a fresh air supply the air control setting is reduced.
  • Page 5: Warranty

    For this reason it is important to www.nordpeis.com increase the air supply just after adding logs. Choice of fuel All types of wood, such as birch, beech, oak, elm, ash and fruit trees, can be used as fuel in the insert.
  • Page 6 oak and birch has the highest density. Attention! We do not recommend using fuel briquettes/ compact wood in our products. Use of such fuel may cause the product to overheat and exceed the temperatures determined safe. Burning briquettes/ compact wood is done so at your own risk and only small amounts (max 1/3 of normal load) should be used for each load.
  • Page 7 Some advice in case of combustion problems Error Explanation Solution The chimney is blocked Contact a chimney sweeper / dealer for more information or clean The flue is sooty or there is accumulated soot on the the flue, smoke baffle and burn chamber. No draught smoke baffle The smoke baffle is wrongly positioned...
  • Page 8 Bergen = mm Bergen air 272,50 Ø155...
  • Page 9 FIG 1 =Brannmur/Brandmur/Palomuuri/ / Firewall/Mur parefeu/Hitzenschutzwand =Brennbart materiale/Brændbart materiale/ Brännbart material/ Tulenarka materiaali/Combustible material Matières combustibles/Brennbarem Material >400 >400 >20 >10 >300 >300...
  • Page 10 FIG 2 FIG 3 FIG 4 FIG 5...
  • Page 11 FIG 6 FIG 7 FIG 8 FIG 9 Nordpeis AS, Gjellebekkstubben 11, N-3420 LIERSKOGEN, Norway www.nordpeis.no...

Table of Contents